Forwards Topical Rept Evaluation of BAW-10156, LYNXT-Core Transient Thermal Hydraulic Program. Rept Acceptable for Ref in License Applications
ML20138C476
Person / Time
Issue date: 12/03/1985
From: Berkow H
Office of Nuclear Reactor Regulation
To: Taylor J
BABCOCK & WILCOX CO.
Shared Package
ML20138C481 List:
References
NUDOCS 8512130028
Download: ML20138C476 (2)


Text

.

December 3, 1985 Mr. J. H. Taylor, Manager Licensing Services Babcock & Wilcox 3315 Old Forest Road Post Office Box 10935 Lynchburg, Virginia 24506-0935

Dear Mr. Taylor:

SUBJECT:

ACCEPTANCE FCR REFERENCING OF LICENSING TOPICAL REPORT BAW-10156, ULYNXT-CORE TRANSIENT THERMAL-HYDRAULIC PROGRAM" We have completed our review of the subject topical report submitted by Babcock & Wilcox (B&W) by letter dated January 20, 1984. We find the report to be acceptable for referencing in license applications to the extent specified and under the limitations delineated in the report and the associated NRC evaluation, which is enclosed. The evaluation defines the basis for acceptance of the report.

We do not intend to repeat our review of the matters described in the report and found acceptable when the report appears as a reference in license applications, except to assure that the material presented is applicable to the specific plant involved. Our acceptance applies only to the matters described in the report.

In accordance with procedures established in NUREG-0390, it is requested that B&W publish accepted versions of.this report, proprietary and ncn-proprietary, within three months of receipt of this letter. The accepted versions shall incorporate this letter and the enclosed evaluation between tne title page and the abstract. The accepted versions shall include an -A (designating accepted) following the report identification symbol.

Should our criteria or regulations change such that our conclusions as to the acceptability of the report are' invalidated, B&W and/or the applicants referencing the topical report will be expected to revise and resubmit their respective documentation, or submit justification for. the continued effective applicability of the topical report without revision of their respective documentation.

Sincerely, DISTRIBUTION:

iCentral File 17

'SSPB~Rea' ding " RDiggs PDR YHsii, CPB Original signed by DCS Herbert N. Berkow, Director PNoonan Standardization and Special HBernard Projects Directorate HBerkow- Division of PWR Licensing-B

Enclosure:

Q As stated <0 1 0

P SSPD i

dden):ac na PD Dh H8er V h / h

/3 /85 8 5 11/;/85 8512130028 851203 PDR TOPRP ENVBW C

PDR [

c

f* / o,, UNITED STATES 8 o NUCLEAR REGULATORY COMMISSION f g .r WASHINGTON, D. C. 20555 f December 3, 1985 i  % .. . . . #o I

Mr. J. H. Taylor, Manager Licensing Services i Babcock & Wilcox 3315 Old Forest Road l Post Office Box 10935 l Lynchburg, Virginia 24506-0935

}

Dear Mr Taylor:

f

[

SUBJECT:

ACCEPTANCE FOR REFERENCING OF LICENSING TOPICAL REPORT BAW-10156,

'llLYNXT-CORE TRANSIENT THERMAL-HYDRAULIC PROGRAM" We have completed our review of the subject topical report submitted by Babcock & Wilcox (B&W) by letter dated January 20, 1984. We find the report to be acceptable for referencing in license applications to the extent specified and under the limitations delineated in the report and the associated NRC evaluation, which is enclosed. The evaluation defines the basis for acceptance of the report.

We do not intend to repeat our review of the matters described in the report

, and found acceptable when the report appears as a reference in license applications, except to assure that the material presented is applicable to the specific plant involved. Our acceptance applies only to the matters described in the report.

( In accordance with procedures established in NUREG-0390, it is requested that 1 B&W publish accepted versions of this report, proprietary and non-proprietary,

, within three months of receipt of this letter. The accepted versions shall r

incorporate this letter and the enclosed evaluation between the title page and L the abstract. The accepted versions shall include an -A (designating L

accepted) following the report identification symbol.

Should our criteria or regulations change such that our conclusions as to the acceptability of the report are invalidated, B&W and/or the applicants referencing the topical report will be expected to revise and resubmit their respective documentation, or submit justification for the continued effective

. applicability of the topical report without revision of their respective i documentation.

l Sincerely,

. w 1

erbert N. Berkow, Director i Standardization and Special Projects Directorate Division of PWR Licensing-B

Enclosure:

As stated i . . _ . - - _ . _ - . . _ _ . _ . _ ._ _

, . _ . .- _._ __ , , _ . _ _ _ .