NSD-NRC-98-5796, Notifies NRC That Approved Process in WCAP-12488-A Being Used to Account for Design Mods for 17X17 Rfa with Ifm Grid Design as Required by Fcep SER
| ML20154M323 | |
| Person / Time | |
|---|---|
| Site: | Wolf Creek |
| Issue date: | 10/13/1998 |
| From: | Sepp H Westinghouse, Div of CBS Corp |
| To: | Collins T NRC/IRM |
| References | |
| NSD-NRC-98-5796, NUDOCS 9810200236 | |
| Download: ML20154M323 (1) | |
Text
.. _ . __. _ ._ _ __ _ _ . . . . _ _ _ . _ _ . _ . _ _ _
! /' D ~
=*
. { ' e*
l 6
l 1
- n. .
Westinghouse Energy Systems Box 355
. Electric Corporation Pittstegh PennsyNania 15230 0355 I October 13,1998 )
U.S. Nuclear Regulatory Commission gv
- ATTN: Document Control Desk h Washington,DC 20555 9- ;
l Attention: T. E. Collins, Chief l Reactor Systems Branch j j Division of Systems Safety and Analysis i l
Subject:
Fuel Criteria Evaluation Process Notification for the 17X17 Robust Fuel Assembly with IFM Grid Design
Reference:
Letter from N. J. Liparuto (Westinghouse) to J. E. Lyons (NRC), " Transmittal of Response to NRC Request for Information on Wolf Creek Fuel Design Modifications,"
NSD-NRC-97-5189, June 30,1997 1
Dear Mr. Collins:
l The NRC was notified in the above reference that the Westinghouse Fuel Criteria Evaluation Process j
! ~(FCEP) was being used to account for design modifications specific to Wolf Creek fuel. The Wolf Creek ,
L design modifications (i.e., Modified VANTAGE 511 (V511) Lov7 Pressure Drop (LPD) mixing vane grids, 1 Modified V511 Intermediate Flow Mixer (IFM) grids, and thicker walled thimble and instrument tubes) are 1 l now being generically applied to 17X17 V511 fuel in other Westinghouse plants as part of a Robust Fuel Assembly (RFA) program. This letter serves as Westinghouse notification to the NRC, as required by the
[ FCEP SER, that the NRC-approved process in WCAP-12488-A is being used to account for the design
! modifications for the 17X17 RFA with IFM grid design. The above reference concluded that the WRB-2 DNB correlation is applicable to the modified Wolf Creek assembly design. This conclusion also applies to L the generic 17X17 RFA with IFM grid design. Initial application of this generic FCEP notification is planned for the Salem Unit 2 Cycle 11 fuel region which is planned to be inserted into Salem Unit 2 in May 1999.. } l
\ D J
l Very truly yours, p' l' I II. A. Sepp, Manager Regulatory and Licensing Engineering -
cc: P. C. Wen, NRR/DRPM/PGEB (10115)
I . _ . _ __. _ J