Jump to navigation Jump to search
Partially Withheld Insp Repts 50-250/87-05 & 50-251/87-05 on 870120-21 (Ref 10CFR2.790(d) & 73.21).Violation Noted: Failure to Provide Positive Access Control to Vital Area
ML20210T846
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 02/05/1987
From: Mcguire D, Tillman A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20210T790 List:
References
50-250-87-05, 50-250-87-5, 50-251-87-05, 50-251-87-5, NUDOCS 8702180323
Download: ML20210T846 (1)


See also: IR 05000250/1987005

Text

.. -

SAFEGUARDS UNITED STATESINFORMATION

/pGooq*o NUCLEAR REGULATORY COMMISSION

d

[" ,

o REGloN 11

y

  • I

., j -101 MARIETTA STREET, N.W.

e ATLANTA, GEORGI A 30323

%...../ FE8101987

s \

3

Report No.: 50-250/87-05 and;50-251/87-05

Licensee: Florida Power and, Light Company *

'

< ,

9250 West Flagler Street

'

,

' '

Miami, FL 33102 v ' '

Docket Nos.: 50-250 and 50-2515~ , " Lice'nse Nos[: DPR-31 and DPR-41

Facility Name: Turkey Point 3 and 4

~

Inspection Conducted: January 20-21, 1987

Inspector: _

M&$1{fVtWf G A~YY7

i 4A. Ti lia , sical Security Inspector Date Signed

V

Approved by: g ~ W 2 b8k

D. R. McGuire, Chief, Physical Security Section Date Signed

i Nuclear Materials Saftey and Safeguards Branch

i

Division of Radiation Safety and Safeguards

I

'

SUMMARY

Scope: This inspection included a review of the ciccumstances of a licensee

reported incident of failure to provide pcsitive accon control to a vital area

as a result of a posted security officer being asleep on pest as observed by the

NRC Eesident Inspector on January 15, 1987. In addition, *. concern regarding

the degradation of the protected area barrier identified by the NRC Resident

Inspector on January 14, 1987, was also reviewed.

Results: A violation of regulatory requirements relating to the failure to

provide positive access control to a vital area was confirmed.

ENCLOSURE CONTAINS

$AFEGUARDS INFORMATI0!i

870218 5 0 50 U: 0;l 3*PARAT10!! THIS

PDR A0 PDR

O FAC% 73 DECC:!INLLED.

I

SAFEGUARDS INFORMATION

.

_ _ _ _ _ _ _ . _ _ _