TAC:60913
From kanterella
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Request for: Approved, Closed | |
Questions Answers | |
From | |
MONTHYEARML20081C2221984-03-0909 March 1984
[table view]Forwards Application for Amend to License DPR-40,revising Tech Specs to Add Limiting Conditions for Operation, Surveillance Requirements & Administrative Requirements,Per NUREG-0737 ML20091C4641984-05-22022 May 1984 Forwards Calculations Supporting Util Position That During Seismic Event,Attachments to Masonry Walls Would Fail Prior to Pull Out,Per 840206 Request for Addl Info Re IE Bulletin 80-11, Masonry Wall Design ML20133P0101985-02-0202 February 1985 Requests That Requirements for mid-cycle Insp of Steam Generators Be Waived on Basis of Encl Info & Provides Info on Programs to Reduce Recurrence of IGSCC & IGSCC- Induced Steam Generator Tube Failure ML20102B7041985-03-0101 March 1985 Forwards Formal Responses to NRC Questions Re 850202 Justification That mid-cycle Insp of Steam Generators Unwarranted.Response Includes Epri/Util Secondary Side Chemistry Program Comparison ML20138F5681985-12-0909 December 1985 Notifies That 16 Tubes Plugged in Steam Generator RC-2A & 17 Plugged in Generator RC-2B During Inservice Insp Conducted During 1985 Refueling & Maint Outage,Per Tech Spec 3.3(2)e(i).Details Will Be Provided in 6-month Rept ML20138R4881985-12-17017 December 1985 Suppls 840619 Submittal Outlining Installation of in-line Injection of Boric Acid to Secondary Side of Facility. Maintaining Concentration of Acid Should Reduce Denting in Steam Generators & Prevent IGSCC ML20154H8551986-02-21021 February 1986 Special Rept on Steam Generator Denting Derived from 1985 Eddy Current Insp Data for Fort Calhoun Station ML20154H8271986-02-21021 February 1986 Forwards Special Rept on Steam Generator Denting Derived from 1985 Eddy Current Insp Data for Fort Calhoun Station. Rept Should Also Be Used to Fulfill Eddy Current Reporting Requirements ML20211G3361987-02-12012 February 1987 Forwards Safety Evaluation Re 860221 Special Rept on Steam Generator Tube Denting Derived from 1985 Eddy Current Insp Data.Corrective Actions,Including Improving Secondary Chemistry Limits,Appropriate ML20211G3681987-02-14014 February 1987 Safety Evaluation Re 860221 Special Rept on Steam Generator Tube Denting Derived from 1985 Eddy Current Insp Data. Corrective Actions Appropriate & Steam Generators Acceptable for Continued Operation 1985-02-02 |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:60913&oldid=3250655"