TAC:62972
From kanterella
Request for: Approved, Closed | |
Initiation
Questions Answers | |
From | |
MONTHYEARML20210D6961986-09-15015 September 1986
[table view]Informs of Results of Cycle 3 Startup Physics Tests Conducted Using Method Described in, Rod Bank Worth Measurement Utilizing Bank Exchange. Ref Bank,Shutdown C, Worth Measured 14% Below Predicted Value ML20211A1961986-09-19019 September 1986 Cycle 3 Startup Rept ML20212G3471987-01-13013 January 1987 Ack Receipt of 860915 Rept of Rod Exchange Test.Overly Large Rod Worth Deviation as Compared to Ref Bank Attributed to Util Failure to Follow Methodology in WCAP-9863-A ML20207R7451987-03-11011 March 1987 Forwards Revised Responses to Questions 6 & 7 Re Determination of Rod Worth Using Rod Swap Methodology,Per Ds Hood 870112 Request & 870219 & 0310 Telcons Between Ds Hood & SA Gewehr 1986-09-19 |