Discusses Leaking High Pressure Hoses on MSA Model 401 self- Contained Breathing Apparatus.Failures Appear to Be Caused by Conditions at Portland Training Ctr,Not by Generic Problem.No Further Action Warranted Unless Problem Recurs
ML20197F864
Person / Time
Issue date: 11/15/1982
From: Black K
NRC OFFICE FOR ANALYSIS & EVALUATION OF OPERATIONAL DATA (AEOD)
To: Heltemes C
NRC OFFICE FOR ANALYSIS & EVALUATION OF OPERATIONAL DATA (AEOD)
References
TASK-AE, TASK-N210 AEOD-N210, NUDOCS 8301060510
Download: ML20197F864 (2)


Text

r I #o UNITED STATES g

8 o NUCLEAR REGULATORY COMMISSION g f, . ,i wasmucrow, o. c. 20sss g

\,*****/

NOV 151982 AE0D/N210 MEMORANDUM FOR: C. J. Heltemes, Jr., Deputy Director Office for Analysis and Evaluation of Operational Data FROM: Kathleen M. Black, Chief Nonreactor Assessment Staff Office for Analysis and Evaluation of Operational Data

SUBJECT:

ENGINEERING EVALUATION - LEAKING HOSES ON SELF CONTAINED BREATHING APPARATUS (SCBA)

MANUFACTURED BY MSA At the recent Agreement States meeting, Marshall Parrott of Oregon mentioned that the Oregon Fire Department found three leaking high pressure hoses on SCBA manufactured by MSA.

On November 5, I spoke to Joe Bigler (412-273-5149), Product Manager at MSA. He provided the following infomation.

. The leaking hoses were part of MSA's Model 401 SCBA. This model is used at nuclear facilities. The hoses have a kevlar lining with a neoprene exterior.

. MSA does not believe it has a generic problen with high pressure hoses for the following reasons.

. The three failures experienced by the Portland fire department occurred at their training center, where units see much more use than they would ordinarily experience. When Portland had the failures, they began a testing program on some 200+ other masks they owned and found no failures.

. When MSA was infomed of the failures, they began an internal testing program. They found no failures.

The conclusion by MSA was that conditions at the Portland training center

! were responsible for the failures.

i l MSA is working on a new model SCBA that will operate with higher pressure

! air than the Model 401. (The use of higher pressure air will extend the time period of SCBA use). This new model will have hoses with a stainless steel inner liner, a braided cover and a nylon outer shell. Once NIOSH has approved the new model, the new hoses will be used on it, as well as the older, lower pressure Model 401 (i.e., only one design of high pressure here will be used by MSA.). The new hoses-can also be used-to-replace hoses on existing Model 401's. ,e ,

_fhkh

I N

~

NOV 151982 The Portland fire department will replace hoses on all of their model 401 masks with the new high pressure hoses because they are concerned that the firemen have lost confidence in the existing units.

Because MSA does not believe they have a generic problem with high pressure hoses, they did not inform NRC of the failures. They did alert NIOSH.

Based on the facts conveyed by Joe Bigler, I agree that the failures appear to be caused by the conditions of use at the Portland training center.

Unless there are other incidents of hose failure, no further action by AE0D appears warranted.

1s G Kathleen M. Black, Chief Nonreactor Assessment Staff Office for Analysis and Evaluation of Operational Data