ML20198L542

From kanterella
Revision as of 21:56, 20 November 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Informs of Confirmation That Tucker Wireline Had Stated That Source Assembly Was Welded Prior to Utilization.Only Issue W/Welds Regarded Tack Welds Vs 360 Degree Weld
ML20198L542
Person / Time
Issue date: 09/03/1997
From: Cruz J
NRC
To: Compton E
NRC
Shared Package
ML20198L519 List:
References
SSD, NUDOCS 9710270070
Download: ML20198L542 (1)


Text

I

,t p

Frome Jeffrey Crus To TWD2.TWP8 (EBC) 6YIC ,00to[C(\

Date 9/3/97 5:58pm

. subject Tucker -Forwarded -Reply Item 1) I checked my notes and telephoned Tucker Wireline today to confirm that they had stated that this particular source assembly WAS welded prior to utilization. Mr. Calvin Wilson (Tucker's General Manager) stated that the only issue with the welds regarded the tack welde versus the 360 degree weld.

You may have been confused by the fact that Amersham did not weld the pieces, but Gammatron (located in Tulsa) performed the weld after source loading.

Item 2) As for the sources being used.out of the Victoria office, I discussed this with my branch chief and he did not think that the identification of the STORAGE location of the sealed cource (in between commercial well logging jobs) was required.

My branch chief informed me that Bruce Carrico has already concurred on the report, and the report is with Division Management for final review.

Y h02{0070 880 PDR

{7102d'(10 v{