MONTHYEARML0324615012003-09-0303 September 2003 Issuance of Amendment No. 250, Revised Spent Fuel Pool Loading Pattern Project stage: Approval ML0324717122003-09-0303 September 2003 Technical Specifications for Amendment No. 250, Revised Spent Fuel Pool Loading Pattern Project stage: Other 2003-09-03
[Table View] |
|
---|
Category:Technical Specifications
MONTHYEARML24198A0722024-08-21021 August 2024 Correction to Issuance of Amendment No. 333 Revision to Technical Specifications to Adopt TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b ML24031A6442024-03-14014 March 2024 Issuance of Amendment No. 282 to Modify Technical Specification 3.3.1, Reactor Pressure System (RPS) Instrumentation, Turbine Trip Function on Low Control Oil Pressure ML23348A3572023-12-14014 December 2023 Application to Revise Technical Specifications to Use Online Monitoring Methodology – Slides and Affidavit for Pre-Submittal Meeting 0CAN042301, Radioactive Effluent Release Report for 20222023-04-14014 April 2023 Radioactive Effluent Release Report for 2022 ML22104A2222022-05-12012 May 2022 Issuance of Amendments Revise Technical Specifications to Adopt TSTF 554 ML21279A2312021-10-0606 October 2021 Application to Revise Technical Specifications to Adopt TSTF-554, Revise Reactor Coolant Leakage Requirements Using the Consolidated Line-Item Improvement ML21208A4492021-09-20020 September 2021 Issuance of Amendment No. 325 Revise Loss of Voltage Relay Allowable Values and Number of Degraded Voltage Channels ML21088A4332021-04-14014 April 2021 Issuance of Amendment No. 324 Adoption of Technical Specification Task Force Traveler, TSTF-569, Revision 2, Revise Response Time Testing Definition ML21027A4282021-03-23023 March 2021 Issuance of Amendment No. 272 Replacement of Reactor Building Spray Sodium Hydroxide Additive with a Passive Reactor Building Sump Buffering Agent 1CAN022102, Supplement Related to License Amendment Request to Replace the Reactor Hydroxide Additive with a Passive Reactor Building Sump Buffering Agent Sodium Tetraborate2021-02-22022 February 2021 Supplement Related to License Amendment Request to Replace the Reactor Hydroxide Additive with a Passive Reactor Building Sump Buffering Agent Sodium Tetraborate ML20160A1472020-06-30030 June 2020 Issuance of Amendment No. 270 to Adopt TSTF 563, Revision 0, Revise Instrument Testing Definitions to Incorporate the Surveillance Frequency Control Program ML20135H1412020-06-30030 June 2020 Issuance of Amendment Nos. 269 and 321 Request to Incorporate the Tornado Missile Risk Evaluator Into the Licensing Basis ML19232A3792019-09-19019 September 2019 Correction to Issuance of Amendment No. 264 Adoption of Technical Specifications Task Force Traveler TSTF-425, Revision 3 ML19175A0422019-09-11011 September 2019 Arkansas Units 1 and 2; Grand Gulf, Unit 1; Indian Point 2 and 3; Palisades; River Bend, Unit 1; Waterford Unit 3 - Issuance of Amendments to Adopt TSTF-529, Clarify Use and Application Rules ML17251A2112017-10-10010 October 2017 Issuance of Amendment No. 307 Revision of Steam Generator Technical Specifications to Reflect Adoption of Technical Specifications Task Force Traveler TSTF-510 (CAC MF9654; EPID L-2017-LLA-0222) ML16165A4232017-03-10010 March 2017 Issuance of Amendment No. 257 Adoption of Technical Specifications Task Force Traveler TSTF-545, Revision 3, ML16027A1092016-02-24024 February 2016 Issuance of Amendment Nos. 255 and 303 Cyber Security Plan Implementation Schedule (CAC Nos. MF6258 and MF6259) ML15096A3812015-04-29029 April 2015 Issuance of Amendment No. 302, Revise Technical Specification Surveillance Requirement 4.1.3.1.2 Note to Eliminate Movement of Control Element Assembly 18 for Remainder of Operating Cycle 24 ML15068A3192015-03-31031 March 2015 Issuance of Amendment No. 301, Request to Adopt Technical Specification Task Force (TSTF)-422, Revision 2, Change in Technical Specifications End States (CE NPSD-1186) ML15023A1472015-03-0303 March 2015 Issuance of Amendment No. 253, Request to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-431, Revision 3, Change in Technical Specifications End States (BAW-2441) ML14356A2272015-02-18018 February 2015 Issuance of Amendment No. 300, Request to Adopt National Fire Protection Association Standard NFPA 805, Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants ML15014A0712015-02-0303 February 2015 Issuance of Amendment No. 252, Request to Revise Technical Specification 5.5.16, Reactor Building Leakage Rate Testing Program, to Extend Type a Test Frequency to 15 Years ML14350B2852015-01-22022 January 2015 Issuance of Amendment No. 299, Revise Technical Specification 6.5.16, Containment Leakage Rate Testing Program, for Requirements for Containment Building Emergency Escape Air Lock Doors ML14254A1332014-11-24024 November 2014 Issuance of Amendment No. 250, Adoption of Technical Specifications Task Force (TSTF)-500, Revision 2, DC Electrical Rewrite - Update to TSTF-360 1CAN111401, Arkansas Nuclear One, Unit 1, License Amendment Request Update the Reactor Coolant System Pressure and Temperature and the Low Temperature Overpressure Protection System Limits2014-11-21021 November 2014 Arkansas Nuclear One, Unit 1, License Amendment Request Update the Reactor Coolant System Pressure and Temperature and the Low Temperature Overpressure Protection System Limits 1CAN111401, License Amendment Request Update the Reactor Coolant System Pressure and Temperature and the Low Temperature Overpressure Protection System Limits2014-11-21021 November 2014 License Amendment Request Update the Reactor Coolant System Pressure and Temperature and the Low Temperature Overpressure Protection System Limits 1CAN101407, Clarifications to Response to Request for Additional Information Associated with Technical Specification Change to Extend the Type a Test Frequency to 15 Years2014-10-28028 October 2014 Clarifications to Response to Request for Additional Information Associated with Technical Specification Change to Extend the Type a Test Frequency to 15 Years 1CAN031401, License Amendment Request - Revised Pages Extend the Type a Test Frequency to 15 Years2014-03-11011 March 2014 License Amendment Request - Revised Pages Extend the Type a Test Frequency to 15 Years 1CAN121302, License Amendment Request Technical Specification Change to Extend the Type a Test Frequency to 15 Years2013-12-20020 December 2013 License Amendment Request Technical Specification Change to Extend the Type a Test Frequency to 15 Years 1CAN081302, Response to Request for Additional Information, Adoption of Technical Specification Task Force (TSTF)-500, Revision 2, DC Electrical Rewrite - Update to TSTF-360.2013-08-28028 August 2013 Response to Request for Additional Information, Adoption of Technical Specification Task Force (TSTF)-500, Revision 2, DC Electrical Rewrite - Update to TSTF-360. 2CAN061302, License Amendment Request - Supplemental Technical Specification (TS) Change Related to Revised Fuel Assembly Drop Analysis and Adoption of TSTF-51, TSTF-272, TSTF-286, and TSTF-4712013-06-18018 June 2013 License Amendment Request - Supplemental Technical Specification (TS) Change Related to Revised Fuel Assembly Drop Analysis and Adoption of TSTF-51, TSTF-272, TSTF-286, and TSTF-471 1CAN061301, License Amendment Request, Revision to Technical Specification 2.1.1.1 Reactor Core Safety Limits2013-06-11011 June 2013 License Amendment Request, Revision to Technical Specification 2.1.1.1 Reactor Core Safety Limits 2CAN011301, License Amendment Request - Adoption of Technical Specification Task Force (TSTF)-500, Revision 2 DC Electrical Rewrite - Update to TSTF-3602013-01-28028 January 2013 License Amendment Request - Adoption of Technical Specification Task Force (TSTF)-500, Revision 2 DC Electrical Rewrite - Update to TSTF-360 1CAN011304, License Amendment Request - Adoption of Technical Specification Task Force (TSTF)-500, Revision 2 DC Electrical Rewrite - Update to TSTF-360.2013-01-28028 January 2013 License Amendment Request - Adoption of Technical Specification Task Force (TSTF)-500, Revision 2 DC Electrical Rewrite - Update to TSTF-360. CNRO-2012-00009, Entergy Responses to Request for Additional Information Regarding Changes to the Quality Assurance Program Manual & Associated Plant Technical Specifications Re Staff Qualifications2012-11-20020 November 2012 Entergy Responses to Request for Additional Information Regarding Changes to the Quality Assurance Program Manual & Associated Plant Technical Specifications Re Staff Qualifications 1CAN061201, License Amendment Request Technical Specification Change Associated with Main Feedwater Valves2012-06-19019 June 2012 License Amendment Request Technical Specification Change Associated with Main Feedwater Valves 1CAN081001, License Amendment Request, Technical Specification Change Associated with Main Feedwater Isolation Valves2010-08-24024 August 2010 License Amendment Request, Technical Specification Change Associated with Main Feedwater Isolation Valves 2CAN051001, Response to Request for Additional Information Associated with Core Operating Limits Report References2010-05-17017 May 2010 Response to Request for Additional Information Associated with Core Operating Limits Report References 1CAN021004, Response to Request for Additional Information, Application for Technical Specification Improvement to Adopt TSTF-490, Revision 0, Deletion of E Bar Definition and Revision to RCS Specific Activity Tech Spec.2010-02-28028 February 2010 Response to Request for Additional Information, Application for Technical Specification Improvement to Adopt TSTF-490, Revision 0, Deletion of E Bar Definition and Revision to RCS Specific Activity Tech Spec. ML0931305282009-12-23023 December 2009 License Amendment No. 241, Modified Technical Specification 3.4.9, Pressurizer, to Delete Low Pressurizer Level Limit ML0930601322009-12-23023 December 2009 License Amendment No. 240, Revised Administrative Changes to Technical Specification 5.5.8, Inservice Testing Program, to Adopt TSTF-479-A and TSTF-497-A 1CAN080901, Changes to Reflect Revision to 10 CFR 50.55a Technical Change Travelers - TSTF-479-A and TSTF-497-A2009-08-0505 August 2009 Changes to Reflect Revision to 10 CFR 50.55a Technical Change Travelers - TSTF-479-A and TSTF-497-A 2CAN030901, License Amendment Request, Technical Specification Change to Modify the Mode of Applicability for Emergency Feedwater Actuation Signal2009-03-0202 March 2009 License Amendment Request, Technical Specification Change to Modify the Mode of Applicability for Emergency Feedwater Actuation Signal 1CAN020901, License Amendment Request, Technical Specification Change to Adopt Low Pressure Air Lock Seal Test2009-02-16016 February 2009 License Amendment Request, Technical Specification Change to Adopt Low Pressure Air Lock Seal Test ML0814000372008-09-0808 September 2008 Technical Specifications for Amendment No. 282 Technical Specification Task Force TSTF-490, Rev 0, Deletion of E Bar Definition and Revision to RCS Specific Activity. ML0812203132008-08-28028 August 2008 Tech Spec Pages for Amendment No. 281 Technical Specification Task Force Change TSTF-359, Increased Flexibility in Mode Restraints. ML0823801472008-08-21021 August 2008 License Amendment Request, Technical Specification Change to Extend Integrated Leak Rate Test Interval One-Time ML0814004492008-07-23023 July 2008 Tech Spec Pages for Amendment No. 280 Reactor Coolant System Relocation to TRM (Tac MD8313) 1CAN070804, License Amendment Request Regarding Technical Specification Changes Associated with Adoption of TSTF-3592008-07-21021 July 2008 License Amendment Request Regarding Technical Specification Changes Associated with Adoption of TSTF-359 2CAN070805, License Amendment Request Regarding Technical Specification Change to Add LCO 3.0.8 on the Inoperability of Snubbers and Relocate TS 3.7.8 to the TRM2008-07-21021 July 2008 License Amendment Request Regarding Technical Specification Change to Add LCO 3.0.8 on the Inoperability of Snubbers and Relocate TS 3.7.8 to the TRM 2024-08-21
[Table view] |
Text
f1.-
REFUELING OPERATIONS FUEL STORAGE LIMITING CONDITION FOR OPERATION 3.9.12.a Storage Inthe spent fuel pool shall be restricted to fuel assemblies having initial enrichment less than or equal to 4.55 +/- 0.05 wlo U-235. The provisions of Specification 3.0.3 are not applicable.
3.9.12.b Storage In the spent fuel pool shall be further restricted by the limits specified In Figure 3.9.2. The provisions of Specification 3.0.3 are not applicable.
3.9.12.c The boron concentration Inthe spent fuel pool shall be maintained (at all times) at greater than 2000 parts per million.
APPLICABILITY: During storage of fuel in the spent fuel pool.
ACTION:
Suspend all actions involving the movement of fuel Inthe spent fuel pool If it Is determined a fuel assembly has been placed in an Incorrect location until such time as the correct storage location is determined. Move the assembly to Its correct location before resumption of any other fuel movement.
Suspend all actions Involving the movement of fuel Inthe spent fuel pool If It Is determined the pool boron concentration is less than 2001 ppm, until such time as the boron concentration is increased to 2001 ppm or greater.
SURVEILLANCE REQUIREMENTS 4.9.12.a Verify all fuel assemblies to be placed Inthe spent fuel pool have an initial enrichment of less than or equal to 4.55 +/- 0.05 wlo U-235 by checking the assemblies' design documentation.
4.9.12.b Verify all fuel assemblies to be placed in the spent fuel pool are within the limits of Figure 3.9.2 by checking the assemblies' design and bumup documentation.
4.9.12.c Verify at least once per 31 days the spent fuel pool boron concentration Is greater than 2000 ppm.
ARKANSAS - UNIT 2 3/4 9-14 Amendment No. 43.,478,224, 250
Figure 3.9.1 Deleted ARKANSAS - UNIT 2 3/4 9-15 Amendment No. 4&,250
Figure 3.9-2 Pattern I BC BC Pattern2 F x Pattern 3 F CC BC BC X F cc lccI orA orA Pattern 4 Fc C Pattern 5 B C C Fc C C Legend:
- 1. Type 7F' - fresh fuel assemblies with an initial enrichment less than or equal to 4.55+/-0.05 wt%.
- 2. Type "BT - an assembly with a maximum Initial enrichment of 4.1 wt%, a minimum burnup of 11.3 GWD/IMTU and zero years cooling time.
Typically "B"type assemblies have only one cycle of bumup.
- 3. 'Fc' - fresh fuel assemblies with an initial enrichment of less than or equal to 4.55+/-0.05 wt% with a CEA Inserted. The CEA must be of the new design.
- 4. "A' - an assembly that meets specific bumup requirements that are Included InTable 1 below.
- 5. "BC" - a "B" type assembly with a CEA inserted. This CEA may be of the old or new design.
- 6. 'C"- a high bumup assembly that meets specific bumup requirements that are included in Table 2 below. Initial enrichment Is less than or equal to 4.50+/-0.05 wt%.
- 7. "AC" - an WA" type assembly with a CEA Inserted. This CEA may be of the old or new design.
- 8. "CC"- a "C"type assembly with a CEA inserted. This CEA may be of the old or new design. Iitial enrichment Is less than or equal to 4.50+/-0.05 wt%.
- 9. "X - a water cell with no fuel.
Note: Any less restrictive assembly may be substituted for another assembly within the pattem. Fuel assembly types are ranked I through 9, with the highest reactivity ranking being 1.
ARKANSAS - UNIT 2 3/4 9-16 Amendment No. 4;.,48, 250
Figure 3.9-2 Allowable Pattern Interfaces Pattern I BC BC F X Pattern 2 orA or Al BC BC X F orA orA _
l CC Pattern 3, Alternate cICCI CC ElFc lC lPattern4 C Fc II FgB 1 Pattem 5 lI B C1 1 atm ARKANSAS - UNIT 2 3/4 9-17 Amendment No. 250
Figure 3.9-2 Allowable Pattern Interfaces Pattern 2 X F CC CC Pattern 3,Alternate Alternate [
F X l F. CC EI lCC F Pattern 3, Alternate CC CC l Fc lC lPattern4 llC lFc l I [
I II FC 7 Pattemr 5,Atemate Pattern 4,Alternate ARKANSAS - UNIT 2 3/4 9-18 Amendment No. 250
e -
1 !. c Figure 3.9-2 Allowable Pattern Interfaces I
Pattern 3 F cc Fc C Pattern 4 I
CC CC I I
I I
I C I l C l Pattern 5, Altemate I B C I
I C Fc Pattern 4, Pattern 5 Alternate Fc C q Pattern 5, Altemate I 5,
~~~~Pattern ,Alternate ARKANSAS - UNIT 2 314 9-19 Amendment No. 250
i
.1 .
k' - 11%
Figure 3.9-2 Table 1 Minimum Bumup Requirements for WAAssemblies at Varying Enrichment and Cooling Time BURNUP, MWD1KgU Average 0 Years 5 Years 10 Years 15 Years 20 Years Enrichment, Cooling lime Cooling Time Cooling Time Cooling Time Cooling Time wt% U-235 2 7.56 7.56 7.56 7.56 7.56 2.5 14.94 14.21 13.47 12.74 12.00 3.0 21.30 20.30 19.30 18.30 17.30 3.5 27.10 25.95 24.80 23.65 22.50 4.0 32.67 31.38 30.09 28.79 27.50 4.5 39.30 37.73 36.15 34.58 33.00 4.95 45.00 43.33 41.65 39.98 38.30 Table 1-1 Bounding Polynomial Fits to Determine Minimum Acceptable Bumup for WKType Assemblies Storage as a Function of Initial Enrichment Decay Time, Bumup, MWDIKgU Years 0 0.68
- E - 16.60 Note: E = Initial average enrichment in wt%oU-235 ARKANSAS - UNIT 2 314 920 Amendment No. 250
N t.
i 'e - 4, -,
Figure 3.9-2 Table 2 Minimum Bumup Requirements for uC" Assemblies at Varying Enrichment and Cooling lime BURNUP, MWD/KgU Average 0 Years 5 Years 10 Years 15 Years 20 Years Enrichment, Cooling Time Cooling Time Cooling Time Cooling Time Cooling Time wt% U-235 2 17.00 15.00 14.00 13.30 13.00 2.5 25.00 22.00 21.00 20.30 20.00 3.0 32.00 29.00 27.00 26.00 25.00 3.5 37.00 35.00 32.50 31.00 30.00 4.0 43.00 40.00 39.00 38.00 37.00 4.5 49.75 46.00 45.00 44.00 43.00 Table 2-1 Bounding Polynomial Fits to Determine Minimum Acceptable Bumup for 'C" Type Assemblies Storage as a Function of Initial Enrichment Decay Time, Bumup, MWD/KgU Years 0 1.3148
- E - 53.6 5 0.3704* E 3 -4.5397" E2 + 29.59
- E3 - 6.5714 E2 + 32.976 E -30.3 15 0.7111
- E -32.0 Note: E = Initial average enrichment in wt% U-235 ARKANSAS - UNIT 2 3/ 9-21 Amendment No. 250
4' 4 DESIGN FEATURES 5.3 Fuel Storage 5.3.1 Spent Fuel Storaae Rack Criticality The spent fuel storage racks are designed and shall be maintained with:
- a. Fuel assemblies stored in the spent fuel pool In accordance with Specification 3.9.12;
- b. kff
- 0.95 If fully flooded with 240 ppm borated water, which includes an allowance for uncertainties as described InSection 9.1 of the SAR; and
- c. kff < 1.0 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the SAR; and
- d. A nominal 9.8 Inch center to center distance between fuel assemblies placed in the storage racks.
5.3.2 New Fuel Storage Rack Criticality The new fuel storage racks are designed and shall be maintained with:
- a. Fuel assemblies having a maximum U-235 enrichment of 4.55+/-0.05 weight percent;
- b. kff
- 0.95 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the SAR;
- c. kff < 0.98 if moderated by aqueous foam, which includes an allowance for uncertainties as described in Section 9.1 of the SAR; and
- d. A nominal 26 inch center to center distance between fuel assemblies placed in the storage racks.
5.3.3 Drainage The spent fuel storage pool is designed and shall be maintained to prevent inadvertent draining of the pool below elevation 399' 101 AS.
5.3.4 Capacity The spent fuel storage pool is designed and shall be maintained with a storage capacity limited to no more than 988 fuel assemblies.
ARKANSAS - UNIT 2 5-2 Amendment No. 24,74,5,4.7,484,205,250