LER 82-043/03L-0:on 820518,during Lake Blowdown Flow Indicator Quarterly Channel Functional Test,Lake Blowdown Flow Instrument Inoperable.Caused by Transmitter Failure. Transmitter Replaced & Loop Check Performed
ML20054G668
Person / Time
Site:  Constellation icon.png
Issue date: 06/16/1982
From: Kay D
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20054G654 List:
References
LER-82-043-03L, LER-82-43-3L, NUDOCS 8206220183
Download: ML20054G668 (2)


Text

-

-- ... D22 1=.17A '> - < n

. ;.. 4 - - G m i %e. ..., i 1,,Ap.'~u OG-5 LICENSEE EVENT RE* ORT g3 March 12, 132 rec: st ocx: l i I I I" I l trtEnt renuT em vee AW. RECUf REC INPC

> e@ 23 0 } 0 l 0101010 l 0 ] O { 01010 lg 4 l1 10 [0 10 lg l l L} LjStClIl .o s ucansaa =sar a as ocu4a w 52 m ucocas c ce i.

1 5i l1 8 1 8 g2v-@ ;c,1c ti !s t g i g g ,

m act l_L.@l0 it to!nlof 60 s1 poCKC ?vsagm 1 17ltgl0 na tre Ev tMT GATE :s 75 atygagT O, ATE 40 w? cEsemmCN ANC P ACB4.BLE CONSEC.!ENCEs @

(

.rino the Lake Blowdown Flow Indicator Quarteriv Channel Functional Test the Lake

- ilowdown Flow Instrumert was inoperable. At the time of this event, LaSalle Unit One The Radwaste Discharge !

_ .as in cold shutdown and there was no irradiated fuel on site.

ealve had been taken out-of-service closed to preclude oossible release of radioactive 1 l

..loulds to iake blowdown line.

_ i I

. ,a .

.. C CW. VALVE sTT*D CMJ3f co- o .~rc=es - su. coo,

. ::e a cc u.AuSI. c=

t w i c iG LE,,jh I C lh l ! l N I S I T I R I U lh 1 l l@ l :oZ l @ sa is s i: n  :  ::

c:=.J a m tNct sie,;>= r m saoutw?)AL -v,e c,

,tvexrv tam atrowT=c. csos a a r.e I 812 l l-l 10 f413l @ I OI 3l {Ll I--I 10l -

h "aVE"P0 ,_,:=*  :: = 24 as  : :s :s Do

,=uwe c=ww.

ca ossamer'

-_ - 1 sme ec w 47 ac>.= ear m**o4

- ac c= su uns s o s te-m f*D*Co =Ou ps.

manaT*ED POaea nut. wrou tA anameyp ad"Tumem A:" nom O'ePLANT

~

  • AACIm W@ l0l0l010l lYj@ lNl@ las A l@ - lRI31619]@

{lglxZ

= l@ lr,s Z l@ :e  :) ao . ** '

st Aa ,,

0.AJ'I OEs: MtmON ANO CORREO"!VE A'. TONS h The trancmitter was (

f _ iThe cause of this occurence was that the transmitter failed.

.lc.anufactured by Rosemont. Model 1151 OP. The transmittar wnc ran1need nnd tha reoni rad I l

l

' loop check was performed. .

l I

? ao sg s .o . ,... mm, @ =: - ,.

@ l i,,B_J@ lj i O ! 01@l NA I

IBl@l

.a .

Test Results

, ,e ,: n aC*ve*'v COMTENT *- LDCKMON OF mELEASE og. g4,sg; e .tLLAss AnacuxT CF ac"'fvf*V US  !

k2! l 2l NA

    • *s so 1 1: t, Pterso ggg gypesvets
      • t O E S CP,'"'1 CN wase t s I Na 1 0 ! 010 !@! Z f@lu so e n  :

l, et=se~~e t i.uua its c .

vwega e ts w'**'Cae I-

. 0'O10j@! Na so I i n  ::

.c:s c == ca .cr t: **cu v .

'** t  : I sO*' P9 Ch l

- i2 G!. .g N t, 2 8206220183 820616 NRC WE W t

' PDR ADOCK 05000373

_ nuyr$9its:...,o w h ya S PDR o

! f1 I1 II't I i 11 !-

s,  :.?

~ r", (815) 357-6761- ext. 499 5 Diane Ka, ,,._,,7

1. LER NUMBER: 82-043/03L-0 I

( II. LASALLE COUNTY STATION: UNIT 1 Ill. DOCKET NUMBER:

050-373 IV. EVENT DESCRIPTION Technical Specification 3 3.7.10 requi res the Lake Blowdown Flow Instrument to be operable. On May 18, 1982, LOS-WL-Q1, Lake Blowdown Flow Indicator Quarterly Channel Functional Test was performed. During this surveillance the Lake Blowdown Flow Instrument was tested and found to be inoperable.

V. PROBABLE CONSEQUENCES OF THE OCCURRENCE At the time of this event, LaSalle Unit One was in cold shutdown and there was no irradiated fuel on site. The probabili ty of any radioactive releases to the river at this time was negligible.

VI. CAUSE

~

The cause of this occurrence was that the transmitter falIed. The trans-

  • mitter was nunufactured by Rosemont, Model 1151DP.

Vll. CORRECTIVE ACTION The Radwaste Discharge Valve had been taken out of service closed on April 19 to preclude possible release of radioactive liquids to the lake blowdown line.

The transmi tter has been replaced and the required- loop check was performed.

Lw ,

Diane L. Kay Prepared by e