LER 82-021/03L-0:on 820315,while in Mode 5,surveillance Testing of ESF Ventilation Sys Filter Train (HV-AES-2) Revealed One HEPA Filter Did Not Meet Air Flow Distribution Criteria.New Filters Installed
ML20054D117
Person / Time
Site:  American Electric Power icon.png
Issue date: 04/13/1982
From: Palmer R
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20054D110 List:
References
LER-82-021-03L, LER-82-21-3L, NUDOCS 8204220357
Download: ML20054D117 (1)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

LICENSEE EVENT REPORT

.. , - CONTROL BLOCK: l l l l l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATiONI lo I td l9l M lLICENSEE l

I I D CODE l C l C14l 2 l@l 0 l0 l 0 LICENSE 15 l 010NUMUEr4 l0 l010 l0 l0 l0 ib l@l4 26 l1 LICENSEl1 l1TYPE l1Jul@lbi LAI l l@

$d cos T loIll i 6 S$RCE0 l L l@l 0 l 5 bl l 0 l 010 l 311 DOCKET NUMBER 68 1669 l@l 01311 EVENT DATE 15 l 812 l@l 14 lb REPORT 014 DATE l 11318 do I 2 l@

EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h 10 !: 1l WHILE IN MODE 5, SURVEILLANCE TESTING 0F THE ENGINEERED SAFETY FEATURE VENTILATION i O i .3 ; l SYSTEM FILTER TRAIN (HV-AES-2) REVEALED THAT ONE HEPA FILTER DID NOT MEET THE AIRl

O l A l l FLOW DISTRIBUTION CRITERIA AS SPECIFIED IN TECHNICAL SPECIFICATIONS 4.7.6.1.d.2. l i

IO lsi l l

10181 l I

10171I 1

I O Is 1 I ,,

C E CODE SUSC E COMPONENT CODE SU8C DE SU E l019l l A l A l@ W@ W @ l XI Xl XI XI Xl XI@ l,Z_j@ [Z_J 18 19 20 s d 9 10 11 12 13 EVENT YE AR RE ORT O CODE Y N LER

@,agg,RO 1812 l ' l-l 1012ill I/l 1013l lLl l-l l Ol

_ 21 22 23 24 26 27 28 29 30 31 32 TAKEN A ON ON PL NT 1 TH HOURS 22 S a if FORT B. SUPPLIE MAN FACTURER lCl@lZl@ lZl@

33 34 35

[jj@

36 l0 l0 l0 l0 l 3# 40 U@

41 l42Yl@ lNl@

43 l44 Al 212l Ol@ 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h ii;o;l ALL NEW HEPA FILTERS WERE INSTALLED, A RETEST WAS PERFORMED AND FOUND TO BE EATIS- l i, ;,, l FACTORY. THE HEPA FILTER THAT DID NOT MEET THE FLOW CRITERIA WAS EXAMINED AND N0  ;

CAUSE FOR FAILURE WAS EVIDENT BY VISUAL INSPECTION. THE FILTER HAD BEEN TESTED ON ,

PREVIOUS OCCASIONS AND FOUND TO BE SATISFACTORY. NO FURTHER ACTION IS PLANNED AT.  ;

, , , , , i THIS TIME.  ;

ST S  % POWE R OTHER STATUS. ISCO RY DISCOVERY OESCRIPTION I i l'a I (G j @ l 0 l 0 l 0 l @ l NA l lBl@lSURVEILLANCETEST I ACTivtTY CO TENT AELEASED OF RELEASE AMOUNT OF ACTivlTY LOCATION OF RELEASE NA iileiL2)@

1 8 9 w @l 10 11 NA 44 l l 45 80 l

PERSONNEL EXPOSURES NUY8ER TYPE DESCRIPTION y l 0l 0l Ol@l Zl@l NA l PERSONNE L INJURIES NUMBER DESCRIPTION NA l t lir l <8l 9l Ol 0 l 0l@l12 11 80 TYPE DESC PTON .

W '@@l NA l PueusTv 8204220357 820413 NRC USE ONLY DESCRIPTION h PDR ADOCK 05000316

  • i 2 n U ISSUED @j NA S PDR l lllllllllllllg ,

J d 0 10 G8 69 80 5 NAME OF PREPARER R. A. PALMER psoye: 616-465-64m 2, l l

I _ __ _ - __ .- - . -. _ _ _ _ _ _