ML20002A800

From kanterella
Revision as of 10:57, 29 February 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards LER 80-042/03L-0
Date released: 01/16/2020 Download: ML20002A800


LER 80-042/03L-0:on 801017,while Performing Special Instruction 4.2.B-5,drywell High Pressure,Switch 2 on PS-64- 58B Operated at 0.07 Psig Above Tech Spec Limits.Caused by Instrument Drift.Switch Recalibr & Retested Satisfactorily
ML20002A804
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 11/14/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20002A804 (2)
Forwards LER 80-042/03L-0
ML20002A799
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 11/14/1980
From: Green H
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References