Forwards LER 80-029/03L-0
Date released: 11/29/2018 Download: ML18082B276


LER 80-029/03L-0:on 800830,during Cooldown,Channel I Pressurizer Overpressure Protection Sys Relief Valve Failed to Open.Caused by Faulty Open Limit Switch on Relief Valve. Sys Depressurized & Vented.Limit Switch Replaced
ML18082B277
Person / Time
Site: Salem PSEG icon.png
Issue date: 09/29/1980
From: Randolph J
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18082B277 (1)
Forwards LER 80-029/03L-0
ML18082B275
Person / Time
Site: Salem PSEG icon.png
Issue date: 09/29/1980
From: Librizzi F
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18082B275 (3)