ML19210E917

From kanterella
Revision as of 02:44, 24 January 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Final Deficiency Rept Re Main Feed Pipe Spools
Date released: 08/12/2019 Download: ML19210E917


Final Deficiency Rept Re Main Feed Pipe Spools.Nrc Found Nine Pipes Not in Compliance W/Asme Code Physical Impact Requirements.One Hot Bend Spool Being Replaced.Others Operate Satisfactorily at Min Svc Temp of 70 F
ML19210E918
Person / Time
Site: Midland
Issue date: 11/19/1979
From: Donna Anderson
BECHTEL GROUP, INC.
To:
References
Download: ML19210E918 (4)
Forwards Final Deficiency Rept Re Main Feed Pipe Spools
ML19210E916
Person / Time
Site: Midland
Issue date: 12/10/1979
From: Howell S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References