ML19210F034

From kanterella
Revision as of 01:35, 24 January 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Interim Deficiency Rept Re Brittle Rebar,Produced by Fl Steel Corp
Date released: 08/12/2019 Download: ML19210F034


Interim Deficiency Rept Re Discovery of Extremely Brittle Rebar Produced by Fl Steel Corp.Caused by High Manganese Content.Defective Rebar Heats Will Be Returned by 791116. Other Heats Found Acceptable
ML19210F035
Person / Time
Site: Phipps Bend Tennessee Valley Authority icon.png
Issue date: 11/15/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19210F035 (2)
Forwards Interim Deficiency Rept Re Brittle Rebar,Produced by Fl Steel Corp
ML19210F033
Person / Time
Site: Phipps Bend Tennessee Valley Authority icon.png
Issue date: 11/15/1979
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19210F033 (1)