Forwards LER 80-004/03L-0
Date released: 11/04/2019 Download: ML19294C220


LER 80-004/03L-0:on 800204,during Routine Surveillance, Reactor Protection Sys Channel B Trip Signal for RCP Underspeed Found Out of Specs.Caused by frequency-to-voltage Converter Being High & Unstable.Unit Replaced & Calibr
ML19294C227
Person / Time
Site: Millstone Dominion icon.png
Issue date: 03/03/1980
From: Bates R
NORTHEAST UTILITIES
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19294C227 (1)
Forwards LER 80-004/03L-0
ML19294C219
Person / Time
Site: Millstone Dominion icon.png
Issue date: 03/03/1980
From: Opeka J
NORTHEAST UTILITIES
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19294C219 (1)