ML19323G170

From kanterella
Revision as of 02:14, 19 January 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Supplementary LER 80-003/01X-2
Date released: 12/03/2019 Download: ML19323G170


Steam Generator Chemistry Study.
ML19323G178
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 02/29/1980
From:
NWT CORP.
To:
References
Download: ML19323G178 (17)
Exam of Prairie Island 2 Inconel Alloy 600 Steam Generator Tube. Portions Withheld (Ref 10CFR2.790)
ML19323G177
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 03/10/1980
From: Aspden R
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML19323G177 (1)
Nondestructive Exam of Prairie Island 2 Steam Generator Tubing.
ML19323G175
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 04/25/1980
From: Klien A
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML19323G175 (14)
Supplementary LER 80-003/01X-2:on 800109,during Eddy Current Testing of Tubes in Unit 2 Steam Generators,Several Indications of Tube Degradation Were Observed.Cause Unstated.Several Tubes Plugged & One Removed for Exam
ML19323G172
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 05/23/1980
From: Hunstad A
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19323G172 (1)
Forwards Supplementary LER 80-003/01X-2
ML19323G169
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 05/23/1980
From: Mayer L
NORTHERN STATES POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19323G169 (1)