ML19323G624

From kanterella
Revision as of 00:56, 19 January 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards LER 80-048/01T-0
Date released: 12/03/2019 Download: ML19323G624


LER 80-048/01T-0:on 800515,w/Unit 1 in Mode 3,test Switches on Containment Purge Exhaust Radiation Monitors Were Discovered to Be in Test Position Making Monitor Inoperable. Caused by Personnel Error.Monitors Restored
ML19323G629
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 05/28/1980
From: Gault G
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323G629 (2)
Forwards LER 80-048/01T-0
ML19323G623
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 05/29/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323G623 (1)