Forwards RO 80-3
Date released: 12/11/2019 Download: ML19331D616


RO 80-3:with Reactor on Mode 4,both Centrifugal Charging Pumps Automatically Started Injecting 535 Gallons of 20,000 Ppm Borated Water at 193 F Into Rcs.Caused by Incorrect Switch Manipulation During Test Performance
ML19331D620
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 08/27/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19331D620 (1)
Forwards RO 80-3
ML19331D615
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 08/27/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References