Proposed Approach for Staff Review of Plant Specific Modelling of Generation-III Shutdown Seals in License Amendment Requests (Lars)
ML18094A000
Person / Time
Issue date: 04/04/2018
From: Brian Benney
NRC/NRR/DLP/PLPB
To:
Benney B
Shared Package
ML18072A211 List:
References
Download: ML18094A000 (1)


Text

Proposed Approach for Staff Review of Plant Specific Modelling of Generation-III Shutdown Seals in License Amendment Requests (LARS)

Generation III Shutdown Seals (GIII-SDS) Modeled in PRA(s)

Used to Support LAR Case 1 (Consistent with review of peer-reviewed PRA)

Verify and review that the licensee:

1. Provided finding level F&Os and Was the GIII-SDS model in Y their resolution AND the PRA peer-reviewed? 2. Described how the staff SE on GIII-SDS is met, all the limitations and conditions (L&Cs) therein are satisfied, and justified any deviations.

N Licensee chooses to not Y credit the GIII-SDS in the LAR? Case 2 Verify and review that the licensee:

1. Demonstrated on the docket (via sensitivity) that the removal of credit for GIII-SDS does not affect the N decision and insights.
2. Clarifies when, and if, the credit will be used.

Did GIII-SDS modeling use a Y Case 3 peer-reviewed WOG-2000 Verify and review that the licensee:

model as foundation? 1. Demonstrated (on a plant-specific OR generic basis) why inclusion of GIII-SDS is N not a PRA upgrade.

2. Described how the staff SE on GIII-SDS is met, all Case 4 the L&Cs therein are Perform a detailed review of GIII-SDS satisfied, and justified any modeling, alignment with staff SE, and deviations.

L&Cs details via audit and RAIs OR Licensee either convenes peer-review or removes credit (follow approach for Case 1 or 2, as appropriate).