ML18100A462

From kanterella
Revision as of 13:14, 7 January 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Nonproprietary & Proprietary Westinghouse Rept, WCAP-13660 & WCAP-13659, Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis for Sgs,Units 1 & 2.Proprietary Rept Withheld
Date released: 11/29/2018 Download: ML18100A462


Forwards Nonproprietary & Proprietary Westinghouse Rept, WCAP-13660 & WCAP-13659, Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis for Sgs,Units 1 & 2.Proprietary Rept Withheld
ML18100A466
Person / Time
Site: Salem PSEG icon.png
Issue date: 05/31/1993
From: SWAMY S A, YANG C Y
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML18100A466 (80)
Forwards Nonproprietary & Proprietary Westinghouse Rept, WCAP-13660 & WCAP-13659, Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis for Sgs,Units 1 & 2.Proprietary Rept Withheld
ML18100A464
Person / Time
Site: Salem PSEG icon.png
Issue date: 05/05/1993
From: LIPARULO N J
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: MURLEY T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
References
Download: ML18100A464 (10)
Forwards Nonproprietary & Proprietary Westinghouse Rept, WCAP-13660 & WCAP-13659, Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis for Sgs,Units 1 & 2.Proprietary Rept Withheld
ML18100A461
Person / Time
Site: Salem PSEG icon.png
Issue date: 07/06/1993
From: HAGAN J J
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML18100A461 (4)