Portable density
gauge was damaged by [an] intoxicated driver while [the]
gauge was in use at approximately 2:00
AM. Licensee personnel were able to retract [the] source rod into [the] damaged case. [The] shielding appeared to be intact. Readings on [the] damaged
gauge at one meter with [the] rod retracted were 0.2 to 0.3 Mr/hr. [The]
Gauge was placed in [a] transport case and returned to [the] licensee's storage location. Licensee performed [a] leak test and is awaiting results. Initial survey of [the] area around [the] damaged
gauge indicated no contamination or evidence of leakage of [the] source.
Gauge to be surveyed, packaged and prepared for shipment by local service provider (Cline Technical Services).
Gauge is a
Troxler Model 4640-B with 8 mCi (millicuries)
Cs-137 source.
Corrective Action: Equipment returned to manufacturer for repair or disposal.
Manufacturer: Troxler Model Number: 4640-B Serial Number: 1122
Item Number: OH050006.