The
Iowa Department of Public Health provided the following report via e-mail:
The Iowa Department of Public Health was informed on 10/28/10 that Registrant number 3272-1-0403, Plasti-Paint, lost a Static Eliminator (SN: A2GV069).
The radionuclide is a 0.01 Ci sealed source of Po-210. The Static Eliminator was manufactured by NRD, Inc, Model number: P-2021-8201. The cause of this loss was human error.
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than
IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as
moisture density gauges or thickness
gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to
http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf