The following was received from the Commonwealth of
Pennsylvania via email:
On August 10, 2016, the Department [Pennsylvania Bureau of Radiation Protection] was notified by Testing Services, Inc. that a moisture/density gauge had been damaged while on location at a temporary job site. It is reportable per 10 CFR 30.50(b)(2).
While at a temporary job site, a Humboldt Model 5001 gauge was damaged and became unusable after being run over by a compactor. A survey of the gauge indicated that the source was still in its shielded position. A leak test sample has been taken and sent for analysis and the gauge has been removed from service and secured. No over exposures have occurred. A service provider has been contacted to see if repairs are possible or if the gauge will be returned to the manufacturer.
Radionuclides: Cs-137 and Am-241:Be
Manufacturer: Humboldt
Model: 5001
Serial Number: 2394
Activity: 11 mCi Cs-137, 44 mCi Am-241:Be
The gauge has been securely stored and placed out of service until repairs/return can be accomplished. The Department has scheduled a reactive inspection. More information will be provided when available.
PA report # PA160022