ENS 53682
ENS Event | |
---|---|
04:00 Sep 11, 2018 | |
Title | Agreement State Report - Damaged Moisture Density Gauge |
Event Description | The following was received from the State of New York by fax:
Terracon Consultants reported that a moisture/density gauge [Troxler model 3430P, serial #70428, containing 0.30 GBq (8 mCi) Cs137 and 1.48 GBq (40 mCi) Am-Be source] was damaged at a mass fill project in Rochester, NY. The source manufacturer and serial number are not yet available. While at a mass fill project in Rochester, NY, a technician had completed a round of density testing and placed the gauge within a roped off area at the end of the fill area. He then walked to his truck approximately 100 feet away to get water. During that time, a 10-ton single drum roller moving in reverse headed towards the roped off area and gauge. The technician noticed the operator approaching the gauge as he walked back towards it and yelled and tried to gain the attention of the roller operator. The rear rubber tire of the roller impacted the side of the gauge and damaged the plastic covering. The technician cordoned off the area 15 feet around the gauge and surveyed the operator and roller. The technician called their office manager and a regional manager (who happened to be in their office) and went to the site and surveyed the gauge and all parties/equipment involved and it did not appear that the gauge was leaking. The gauge was visually inspected for damage and it appeared that only the top case was damaged, the gauge was still operational, and the source rod was fully enclosed in the gauge. The gauge was returned to its transport case and returned to its permanent storage location in Rochester, NY. The gauge will be transported for repair and leak testing. An internal root cause analysis and follow up training with the technician will be set in place with their corporate RSO [Radiation Safety Officer] in the next few days. NY EVENT REPORT ID NO. NY-18-02 |
Where | |
---|---|
Terracon Consultants, Inc. Rochester, New York (NRC Region 1) | |
License number: | C3209 |
Organization: | New York State Dept. Of Health |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+992.4 h41.35 days <br />5.907 weeks <br />1.359 months <br />) | |
Opened: | Daniel J. Samson 12:24 Oct 22, 2018 |
NRC Officer: | Bethany Cecere |
Last Updated: | Oct 22, 2018 |
53682 - NRC Website | |
Terracon Consultants, Inc. with Agreement State | |
WEEKMONTHYEARENS 558622022-04-27T16:48:00027 April 2022 16:48:00
[Table view]Agreement State Damaged Moisture Density Gauge ENS 536822018-09-11T04:00:00011 September 2018 04:00:00 Agreement State Agreement State Report - Damaged Moisture Density Gauge ENS 529832017-09-21T12:59:00021 September 2017 12:59:00 Agreement State Agreement State Report - Damaged Gauge at Construction Site ENS 515412015-11-16T16:15:00016 November 2015 16:15:00 Agreement State Agreement State Report - Damaged Density Moisture Gauge ENS 454102009-10-03T19:00:0003 October 2009 19:00:00 Agreement State Agreement State Report Involving a Stolen Troxler Moisture Density Gauge ENS 434972007-07-17T16:00:00017 July 2007 16:00:00 Agreement State Agreement State Report - Lost Moisture Density Gauge 2022-04-27T16:48:00 | |