The following report was received from the
California Department of Public Health, Radiologic Health Branch (CA
RHB) by email:
On August 30, 2017, the President and
ARSO of Earth-Strata, Inc., contacted the CA
RHB Brea office [at 1415 PDT] to report a moisture/density
gauge had been run over by a bulldozer at a construction site in Santa Clarita, CA. The
gauge is a
CPN MC-3, S/N M36087027 (10 mCi
Cs-137, 50 mCi Am:Be-241). [The licensee] stated that the
gauge was on the ground with the
Cs-137 source in the shielded position when it was struck by the bulldozer. The area around the
gauge was isolated until the
gauge operator was instructed by [the ARSO] to place the
gauge in the transport case for transport to Maurer Technical Services to be inspected and to perform an emergency leak test. [The licensee] stated that the plastic cover of the
gauge had been broken and the guide tube and source rod had broken off of the top of the source shield. [The licensee] stated that after the
gauge was inspected by Maurer personnel, it was determined that the
Cs-137 source remained in the shielded position and the Am:Be-241 source remained intact and was still attached to
gauge. Maurer Technical Services will assist in the disposal of the
gauge. The investigation will remain open and any citations will be deferred until the licensee provides the 30-day report.