Semantic search

Jump to navigation Jump to search
 Issue dateFromTitleProject stage
05000336/LER-1984-005, Confirms That Rev to LER 84-005 Will Be Submitted within 2 Months,Clarifying Performance of Type A,B & C Testing During 1983 Refueling Outage as Discussed in 860604 Meeting18 June 1986Opeka J
NORTHEAST UTILITIES
Northeast Nuclear Energy
Confirms That Rev to LER 84-005 Will Be Submitted within 2 Months,Clarifying Performance of Type A,B & C Testing During 1983 Refueling Outage as Discussed in 860604 MeetingMeeting
A06107, Submits Addl Info Re 10CFR50,App J Integrated Leak Rate Testing Conducted During Fall 1986 Refueling Outage,Per NRC .Preventative Maint Program for Fisher Butterfly Containment Isolation Valves Initiated16 January 1987NORTHEAST UTILITIES
Mroczka E
Sears C
Northeast Nuclear Energy
Submits Addl Info Re 10CFR50,App J Integrated Leak Rate Testing Conducted During Fall 1986 Refueling Outage,Per NRC .Preventative Maint Program for Fisher Butterfly Containment Isolation Valves InitiatedOther
B11113, Forwards Reactor Containment Bldg Integrated Leak Rate Test,850614-16, Third Test in First 10-yr Inservice Period1 November 1985Opeka J
NORTHEAST UTILITIES
Sears C
Northeast Nuclear Energy
Forwards Reactor Containment Bldg Integrated Leak Rate Test,850614-16, Third Test in First 10-yr Inservice PeriodOther
B11839, Advises of Intent to Conduct Type a Tests During Mar 1988, Jan 1991 & Mar 1995,per 10CFR50,App J,Section III.A.6(a). Recent Type a Test Exceeds Max Leakage Rate Specified in Tech Specs.Schedule Ensures Primary Containment Integrity6 November 1985Opeka J
NORTHEAST UTILITIES
Mroczka E
Northeast Nuclear Energy
Advises of Intent to Conduct Type a Tests During Mar 1988, Jan 1991 & Mar 1995,per 10CFR50,App J,Section III.A.6(a). Recent Type a Test Exceeds Max Leakage Rate Specified in Tech Specs.Schedule Ensures Primary Containment IntegrityOther
ML20138R79216 June 1985Northeast Nuclear EnergyReactor Containment Bldg Integrated Leak Rate Test, 850614-16Other
ML20195C78127 May 1986Jaffe D
Office of Nuclear Reactor Regulation
Notification of 860604 Meeting W/Util in King of Prussia,Pa to Discuss Proposed Schedule for Integrated Leak Rate TestMeeting
ML20210G76123 September 1986Thadani A
Office of Nuclear Reactor Regulation
Forwards Safety Evaluation Re Util 851106 Request for Approval of Schedule for Type a Containment Leak Rate Tests. Proposed Schedule Acceptable Provided That Listed Remedial Actions Be Completed During Fall 1986 Refueling OutageApproval
ML20210G78323 September 1986Office of Nuclear Reactor RegulationSafety Evaluation Re Util 851106 Request for Approval of Schedule for Type a Containment Leak Rate Tests.Proposed Schedule Acceptable Contingent Upon Acceptable Type B & C Test Results in Future & Implementation of Maint ProgramsApproval