Semantic search
Jump to navigation
Jump to search
Issue date | From | Title | Project stage | |
---|---|---|---|---|
ML20129E054 | 26 September 1996 | NRC (Affiliation Not Assigned) Shiraki C | Forwards RAI to Complete Review of Licensee 960726 Request to Amend TS to Allow Licensee Control of RCS PT Limits for Heatup,Cooldown,Low Temp Operation & Hydrostatic Testing | RAI |
ML20132F498 | 20 December 1996 | NRC (Affiliation Not Assigned) Shiraki C | Forwards Amends 177 & 164 to Licenses DPR-39 & DPR-48, Respectively & Safety Evaluation.Amends Allow Commonwealth Edison to Control Reactor Coolant Sys Pressure & Temperature Limits for Heatup,Cooldown,Low Temp Operation & Testing | Approval |
ML20134D351 | 18 October 1996 | NRC (Affiliation Not Assigned) Shiraki C | Requests Addl Info Re Proposed Amend That Would Allow Licensee Control to Reactor Coolant Sys Pressure & Temp Limits for Heatup,Cooldown,Low Temp Operation & Hydrostatic Testing | Other |