ML19232A171
ML19232A171 | |
Person / Time | |
---|---|
Site: | 07109341 |
Issue date: | 06/19/2019 |
From: | Alexis Sotomayor-Rivera NRC/NMSS/DSFM/CSRB |
To: | Garcia-Santos N Spent Fuel Licensing Branch |
Garcia-Santos N | |
Shared Package | |
ML19232A170 | List: |
References | |
Download: ML19232A171 (1) | |
Text
5.0 SHIELDING REVIEW 5.1.2 Summary of Maximum Radiation Levels The summary of the maximum dose rates is shown in Table 6
-6 and Table 6
-7 of the application for NCT and HAC, respectively.
For NCT, total dose rates at top of the package surface is computed to be 15.3 mrem/hr, the total dose rates at the side of the package is computed to be 29.7 mrem/hr, and the total dose rates at the bottom of the package is computed to be 4.4 mrem/hr. The total dose rate at t he top of the vehicle surface is computed to be 15.3 mrem/hr, the total dose rates at the side of the vehicle surface, the total dose rate is computed to be 3.5 mrem/hr, and at the bottom of the vehicle surface the total dose rates is computed to be 4.4 mrem/hr.
T he total dose rates at 2 meters fr om vehicle surface is computed to be 0.3 mrem/hr, and the total dose rates at the occupied location is computed to be 4.95 E-02. For HAC, the maximum total dose rates at one meter from the top of the package surface is computed to be 5.2 mrem/hr , the total dose rates at one meter from the side of the package surface is computed to be 1.6 mrem/hr, and the total dose rates from the bottom of the package surface is computed to be 1.8 mrem/hr.