ML18054A204
ML18054A204 | |
Person / Time | |
---|---|
Issue date: | 02/15/2018 |
From: | Diaz-Sanabria Y K NRC/NMSS/DSFM/CSTB |
To: | Gilmore D - No Known Affiliation |
Diaz-Sanabria Y K | |
Shared Package | |
ML18054A201 | List: |
References | |
Download: ML18054A204 (1) | |
Text
From: Diaz-Sanabria, Yoira Sent: Thursday, February 15, 2018 2:38 PM To: 'donnagilmore@gmail.com' <donnagilmore@gmail.com
>
Subject:
FW: ACTION DUE 12/5 Re: Response to Question Holtec UMAX San Onofre dry storage system Donna, I am the supervisor in charge of the thermal reviews for the Division of Spent Fuel Management (DSFM) in the Office of Nuclear Material Safety and Safeguards at the Nuclear Regulatory Commission. My understanding is that you had em ail exchanges with DSFM Director, Michael Layton, regarding the UMAX storage system. In one of the emails you had several questions specifically about the thermal analyses. Please see attached the responses to your questions. Feel free to contact us if you need any additional information.
Yoira Diaz Sanabria