ML18094A000

From kanterella
Revision as of 08:49, 13 September 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Proposed Approach for Staff Review of Plant Specific Modelling of Generation-III Shutdown Seals in License Amendment Requests (Lars)
ML18094A000
Person / Time
Issue date: 04/04/2018
From: Benney B J
NRC/NRR/DLP/PLPB
To:
Benney B J
Shared Package
ML18072A211 List:
References
Download: ML18094A000 (1)


Text

Proposed Approach for Staff Review of Plant Specific Modelling of Generation-III Shutdown Seals in License Amendment Requests (LARS)

Generation III Shutdown Seals (GIII-SDS) Modeled in PRA(s)

Used to Support LAR Was the GIII-SDS model in the PRA peer-reviewed? Case 1(Consistent with review of pee r-reviewed PRA)

Verify and review that the licensee:

1.Provided finding level F&Os and their resolution AND 2.Described how the staff SE on GIII-SDS is met, all the limitations and conditions (L&Cs) therein are satisfied, and justified any deviations. Did GIII-SDS modeling use a peer-reviewed WOG-2000 model as foundation? Case 3Verify and review that the licensee:

1.Demonstrated (on a plant-specific OR generic basis) why inclusion of GIII-SDS is not a PRA upgrade.

2.Described how the staff SE on GIII-SDS is met, all the L&Cs therein are satisfied, and justified any deviations. Case 4 Perform a detailed review of GIII-SDS modeling, alignment with staff SE, and L&Cs details via audit and RAIs OR Licensee either convenes peer-review or removes credit (follow approach for Case 1 or 2, as appropriate). Licensee chooses to not credit the GIII-SDS in the LAR? Case 2Verify and review that the licensee:

1.Demonstrated on the docket (via sensitivity) that the removal of credit for GIII-SDS does not affect the decision and insights. 2.Clarifies when, and if, the credit will be used.

N Y N Y N Y