Notification of limited E7000 relay recall (CII-010).
During our normal assembly processing of nuclear E7000 relays, Tyco Electronics experienced an issue with a component. A spring in the base assembly broke during the calibration process. An analysis of the spring revealed non-conforming heat treatment causing the spring to become brittle. Further investigation revealed that this condition was limited to one specific lot of springs.
The cause of the defect was determined to be stress corrosion cracking (SCC). Testing of other springs in this lot did not identify additional defective springs. Tyco's inspection process has been changed to better detect SCC. The defective springs have been purged from inventory and customers notified.
Plant affected by this recall are:
Braidwood
Farley
Fitzpatrick
Indian Point 3
Limerick
Millstone
North Anna
Oyster Creek
Peach Bottom
Perry
Prairie Island
San Onofre
Susquehana
Vogtle
Watts Bar
Other agencies/organizations:
Delphi Controls
Engine Systems Inc
Entergy Oswego Warehousing
Ergy Tech
GE Nuclear Energy
Progress Energy Carolinas
Trentec Inc - Curtiss-Wright Flow Control Group