ML19242A168

From kanterella
Revision as of 23:26, 23 January 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards LER 79-069/03L-0
Date released: 09/13/2019 Download: ML19242A168


LER 79-069/03L-0 on 790623:during Performance of Surveillance Testing,Containment post-accident Radiation Monitor Re 5029 Had Low Flow Alarm & Was Declared Inoperable.Caused by Loose Sheave Set Screws
ML19242A183
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 07/19/1979
From: Adams J
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19242A183 (2)
Forwards LER 79-069/03L-0
ML19242A167
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 07/19/1979
From: Murray T
TOLEDO EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19242A167 (1)