ML19209B713

From kanterella
Revision as of 06:32, 24 January 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards LER 79-069/03L-0
Date released: 08/11/2019 Download: ML19209B713


LER 79-069/03L-0:on 790908,recurrent Failure of Rod Block Monitor B Began.Caused by Failure of Low Power Range Monitor Loose Switch Connector & Sticky Contacts in Rod Info Relays. Replacement of Relay Card Eliminated Failures
ML19209B719
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 10/05/1979
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19209B719 (2)
Forwards LER 79-069/03L-0
ML19209B712
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 10/05/1979
From: Leonard J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19209B712 (1)