Pages that link to "EMPC"
← EMPC
Jump to navigation
Jump to search
The following pages link to EMPC:
Displayed 4 items.
- 05000272/LER-1981-080-03, /03L-0:on 810824,containment Fan Coil Unit Indicated No Svc Water Flow in High Speed.Caused by Leak of Flow Transmitter 13SW72 from Hole in Weld on Pipe Flange. Pipe Flange Rewelded (← links)
- 05000280/LER-1982-029-01, /01T-0:on 820222,steam Line Flow Instruments for a Main Steam Line,Channels 3 & 4, & B Main Steam Line,Channel 3,reported Inoperable During Startup.Caused by Lack of Power Supply Fuses to Transmitters.Fuses Replaced (← links)
- 05000344/LER-1981-017-03, /03L-0:on 810731,after Increasing Level in C SI Accumulator by 11%,boron Concentration Not Verified within 6-h,per Tech Spec.Caused by Personnel Error.Sample Taken Upon Discovery.Importance of Sample Stressed to Personnel (← links)
- 05000293/LER-1980-092-03, /03L-0:on 801129,reactor Water Cleanup Pumps Tripped & Valve M01201-2 Could Not Be Remotely Operated. Caused by burned-out GE Control Relay Model CR120A04002AA & Blown MCC Panel Fuse for M01201-2 Control Circuits (← links)