Pages that link to "ST-HL-AE-3985, Special Rept:On 911224,control Valve Failed Open Causing Reduction of Reactor Coolant Sys Pressure.Cause Can Not Be Determined.Verified No Loose Connections,High Resistant Contacts or Voltage Fluctuations Present"
Jump to navigation
Jump to search
The following pages link to ST-HL-AE-3985, Special Rept:On 911224,control Valve Failed Open Causing Reduction of Reactor Coolant Sys Pressure.Cause Can Not Be Determined.Verified No Loose Connections,High Resistant Contacts or Voltage Fluctuations Present:
Displayed 18 items.
- ST-HL-AE-3960, Special Rept:On 911212,standby Diesel Generator 11 Nonvalid Failure Occurred Due to High Resistance of Relay Contacts within Instantaneous Preposition Board.Instantaneos Preposition Board Replaced & Similar Relays to Be Inspected (← links)
- ST-HL-AE-3929, Supplement to Special Rept:On 910710,spraying Lube Oil Leak Discovered at Cylinder 7R & Engine Manually Secured.Caused by Break in Exhaust rocker-to-inlet Rocker Crossover Lube Oil Line.Design of Lube Oil Line Changed (← links)
- ST-HL-AE-3951, Special Rept:On 911025,SDG 21 Found to Have Fuel Oil Leak at Injection Pump.Caused by Delivery Valve Holder Design Prone to Cracking.Testing Frequency for Sdg 21 Remains at Once Per 31 Days (← links)
- ST-HL-AE-3937, Special Rept:On 911030,fuel Oil Leak Occurred at Cylinder 5R on High Pressure Fuel Oil Supply Line Connection to Fuel Oil Injector.Evaluation Underway to Determine Cause. Injector & Fuel Oil Line Replaced (← links)
- ST-HL-AE-3928, Special Rept:On 911025,fuel Oil Leak Found at Injection Pump 9L of Standby Diesel Generator 21.Caused by Crack on Threaded Portion of Delivery Valve Holder.Holder Will Be Replaced W/New Cooper-Bessemer Holder by Next Outage (← links)
- ST-HL-AE-5064, Special Rept:On 950401,thirty-two SG Tubes Containing Circumferential Indications & 14 SG Tubes Containing Axial Indications Plugged (← links)
- ST-HL-AE-3801, Special Rept:On 910117,SDG 12 non-valid Failure Occurred. Caused by Unstable Relay Contact Resistance Due to Oxidation.Relays 3/4X1,9/3UP & 10/4EX3 Replaced & Procedure Governing Classification of Sdg Starts Will Be Revised (← links)
- ST-HL-AE-3910, Special Rept:On 911006,standby Diesel Generator 21 Tripped & Coasted to Stop.Caused by Malfunction in Amerace Relays in 62CL Circuit Due to End Life.Relays Replaced (← links)
- ST-HL-AE-3889, Special Rept:On 910904,SDG 22 Failed.Caused by Intermittent Malfunctioning of Instantaneous Preposition Board. Instantaneous Preposition Board Replaced & Applicable Relays in Emergency Mode Tested for Proper Resistance (← links)
- ST-HL-AE-3834, Special Rept:On 910710,spraying Lube Oil Leak Identified at Cylinder 7R & Standby Diesel Generator Declared Inoperable. Caused by Break in Exhaust Rocker to Inlet Rocker Crossover Lube Oil Line.Wall Thickness Tubing Replaced (← links)
- ST-HL-AE-3837, Suppl to Special Rept Re Inoperable Primary Meteorological Tower Instrument.Primary Meteorological Tower Restored to Operable Status on 910627 & Operator Log Procedures for Towers Enhanced (← links)
- ST-HL-AE-3814, Special Rept:On 910616,primary Meteorological Tower Wind Direction Sensor at 60 Meter Elevation Declared Inoperable Due to Indication Problems Resulting in Entry Into Tech Spec 3.3.3.4 Action Statement (← links)
- ST-HL-AE-3739, Special Rept:On 910402,during Low Power Physics Testing, Positive Moderator Temp Coefficient Measured.High Critical Boron Concentration in Reactor Coolant Sys at Beginning of 18 Month Fuel Cycle Caused Mtc to Be Positive (← links)
- ST-HL-AE-3600, Suppl Special Rept:On 900829,two Nonvalid Failures of Standby Diesel Generator 12 Occurred.Maint Completed & Diesel Satisfactorily Tested (← links)
- ST-HL-AE-3574, Special Rept:On 900829,two Nonvalid Failures of Standby Diesel Generator Occurred.Cause Under Investigation. Corrective Actions Will Be Submitted in Supplemental Rept by 901015 (← links)
- ST-HL-AE-4602, Special Rept:On 931007,insp Resulted in Plugging of fifty- One Tubes Between Four Steam Generators.Reasons for Tube Plugging Summarized as Listed (← links)
- ST-HL-AE-3532, Special Rept:On 900711,nonvalid Failure of Standby Diesel Generator 13 Occurred.Caused by Loose Connections on Terminal Points on Test Mode Trip Circuitry.Connections Tightened (← links)
- ST-HL-AE-3531, Special Rept:On 900719,primary Meteorological Tower Instruments Declared Inoperable.Caused by Inconsistent Indication Resulting in Entry Into Tech Spec 3.3.3.4 Action Statement.Calibr Sensor Obtained & Installed (← links)