05000321/LER-1981-052-03, /03L-0:on 810621,low Pressure Core Injection B Inverter R44-S003 Tripped on High Temp & Inverter 2R44-S003 Tripped While Backseating Recirculation Suction & Discharge Valves.Cause of R44-S003 Attributed to Defective Switch: Difference between revisions

From kanterella
Jump to navigation Jump to search
StriderTol Bot insert
 
StriderTol Bot change
 
Line 1: Line 1:
{{Adams
#REDIRECT [[05000321/LER-1981-052-03, /03X-1:on 810621,LPCI Inverter B R44-S003 Tripped, Resulting in Loss of Power to Suction & Discharge Valves & LPCI Injection Valve.Caused by Defective Thermal Temp Switch in Inverter Leg.Switch Replaced]]
| number = ML20009E713
| issue date = 07/09/1981
| title = /03L-0:on 810621,low Pressure Core Injection B Inverter R44-S003 Tripped on High Temp & Inverter 2R44-S003 Tripped While Backseating Recirculation Suction & Discharge Valves.Cause of R44-S003 Attributed to Defective Switch
| author name = Coggin C
| author affiliation = GEORGIA POWER CO.
| addressee name =
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
| docket = 05000321
| license number =
| contact person =
| document report number = LER-81-052-03L-01, LER-81-52-3L-1, NUDOCS 8107280382
| package number = ML20009E704
| document type = LICENSEE EVENT REPORT (SEE ALSO AO RO), TEXT-SAFETY REPORT
| page count = 2
}}
{{LER
| Title = /03L-0:on 810621,low Pressure Core Injection B Inverter R44-S003 Tripped on High Temp & Inverter 2R44-S003 Tripped While Backseating Recirculation Suction & Discharge Valves.Cause of R44-S003 Attributed to Defective Switch
| Plant =
| Reporting criterion =
| Power level =
| Mode =
| Docket = 05000321
| LER year = 1981
| LER number = 52
| LER revision = 3
| Event date =
| Report date =
| ENS =
| abstract =
}}
 
=text=
{{#Wiki_filter:NRC FORM 366 U. S. NUCLEAR REGULATORY COMMISSION (7 77)
LICENSEE EVENT REPORT control block: l l
l l
l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6
lo l i l l G l A l E l I l H l 1 l@l 0 l 0 l 10 l 0 l 0 l 0 l 0 l-l 0 l 0 l@l 4 Il l1 11 l 1 l@l l
l@
7 8 9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE 30 57 CAT 58 con'T "E" E I L l@l 015101010131211 l@l 01612 Il i 811 l@l 017 l Ol 918 l 1 l@
lolil S uR 7
8 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT oESCRIPTioN AND PROBABLE CONSEQUENCES h lo121l'B' LPCI inverter R44-S003 tripped on 4 separate occasions on high temp l [o i3i lresulting in loss of power to
'B' recirc suction and discharge valves l
lo 141 land LPCI injection valve (making RHR B loop inop).
'B' LPCI inverter l
Iolsi12R44-S003 tripped while separately backseating rectrc suction and dis-I lo is i Icha rae valves 2831-F023B and F0318. respectively.
The recirc valves andl 1o171ILPCI injection valve had no power making RHR B loop inop.
There were I
lol81 Ino effects upon public health and safety due to':iis. event.
I 80 7
8 9 E
OE SU C E COMPON ENT CODE SUSCOD'E S
E Lol9l l E I D l@ l_E_j@ l G l@ lG lE IN lE lR lA l@ l F l@ l_Z_J @
'7 8
9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCS
:- REPORT REVISION EVENT YE AR R EPORT NO.
CODE TYPE N O.
@ y"LER/RO1811 l l-l l 01 Sl 21 W
l01 31 W
l-l l01 ug E
21 22 23 24 26 27 28 29 30 31 32 K N AC ON P T
ME HOURS S8 i FC 8.
SUP L MANUF RER lAl@lEl@
lZl@
[Z j@
lo101010l l_,y.j @
(_L}@
l A l@
lE131515l@
33 34 35 36 31 40 41 42 43 44 47 CAUSE DESCRIPT!oN AND CORRECTIVE ACTIONS 11101ITriooina of R44-S003 was attributed to defective switchles) in the in-l I
11 111 Ivorter lools )
These switches will ha ronlaced tn nrovant recorronco lii2i lof this problem.
Cause for 2R44-S003 could not be determined since all I m l alarms were reset and not noted.
Further investigation will be per-l 12 141 Iformed when Unit 2 has an outage of sufficient duration to do so.
I 7
8 9 80 ST
% POWER OTHER STATUS dis O RY DISCOVERY DESCRIPTION Ii I5 I lE_J@ 10 I 7 l 2 l@l NA l
l Al@l Operator Observation l
ACTIVITY CO TENT RELEASED OF RELEASE AMOUNT CF ACTIVITY LOCATION OF RELEASE I1 16l [_L} @ [Lj @ l NA l
l NA l
7 8 9 10 11 44 45 80 PERSONNEL EXPOSURES NUMSER TYPE
 
==DESCRIPTION==
li l 71 101 O l O l@l Z l@l NA l
2 u
a PERSONee't iNau'R,,,
NUMBER DESCRIP TION li la l l Ol 01 Ol@l NA l
7 8 9 11 12 80 TYPE DESCR PTION R l Zl@l NA l
8 9 10 80 PUBLICITY 8107280382 810709 NRC USE ONLY ISSU ED PDR ADOCK 05000321 121 o ] [JJ@ DESCRIPTION l
S PDR l
l l l l l l l l l l l l I ;,
7 8 9 10 68 69 80 5 NN
 
5 O
i.
LER #:
50-321/1981-052 Licensee:
Georgia Power Company Facility Name:
Edwin I. Hatch j
Docket #:
50-321
 
=Narrative=
Report for LER 50-321/1981-052 The
'B' LPCI inverter R44-S003 tripped on overtemperature on four (4) separate occasions.
These trips occurred on 6-10-81 at 0317 CDT, 6-18-81 at 0010 CDT, 6-18-81 at 1217 CDT, and 6-21-81 at 1850 CDT and were reported on deviation report numbers 1-81-119, 1-81-128, 1-81-130, and 1-81-134, respec-tively.
The cause of these trips was attributed to defective temperature switch (es) in the inverter leg (s).
All the i
temperature switches will be changed out to prevent recur-rence of this problem.
Following each trip the inverter was reset and returned to service.
The loss of this inverter resulting from an overtemperature trip was reported on LERs j
50-321/1980-082, 092, 102, but was attributed to lack of cool-ing water to the inverter room air conditioner causing a high temperature in the inverter room.
The trip in this report. was attributed to defective temperature switches which is not a repetitive occurrence for this inverter.
I The
'B' LPCI inverter 2R44-S003 tripped on two (2). occasions
~
while separately backseating recirc suction and discharge 1
valves 2B31-F023B and
: F031B, respectively.
These trips occurred on 6-16-81 at 1315 CDT for 2B31-F023B and on 6-16-81 at 1422 CDT f or - 2B31-F031B and were reported on deviation report numbers 2-81-102 and 2-81-104.
The cause for these l
trips could not be determined since the alarms on the inverter I
were reset and not recorded.
A standing order was written.
l requiring operations personn.el to record all alarms prior to returning the inverter (s) to service.
This will give suffic-ient information in the future to determine the cause of an i
inverter trip.
When Unit 2 has an outage of sufficient dura-tion the above valves will be backseated at separate times in an attempt.to simulate the condition that caused this inverter to trip.
The loss of the inverter in the preceding manner is a nonrepetitive occurrence.
l An update report will be issued following the replacement of the temperature switches on R44-S003 and completion of the investigation into the tripping of 2R44-S003.
l l
l f
}}
 
{{LER-Nav}}