CY-04-214, Registration of Spent Fuel Dry Cask in Use at the Haddam Neck Plant (HNP) Independent Spent Fuel Storage Installation (ISFSI): Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:*       CONNECTICUT                               YANKEE               ATOMIC       POWER               COMPANY HADDAM NECK PLANT 362 INJUN HOLLOW ROAD
{{#Wiki_filter:*
CONNECTICUT YANKEE ATOMIC POWER COMPANY HADDAM NECK PLANT 362 INJUN HOLLOW ROAD
* EAST HAMPTON, CT 06424-3099
* EAST HAMPTON, CT 06424-3099
_O1 2OCT    5 20 25~   License No.     CY-04-214 DPR-61 Docket No. 50-213 Docket No. 72-0039 Re: 10 CFR 72.212 Director, Spent Fuel Project Office, Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Attention: Document Control Desk
_O1 2 5 20 CY-04-214 OCT 25 ~
-Washington,-DC 20555 -
License No. DPR-61 Docket No. 50-213 Docket No. 72-0039 Re: 10 CFR 72.212 Director, Spent Fuel Project Office, Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Attention: Document Control Desk
-Washington,-DC 20555 -
Haddam Neck Plant Registration of Spent Fuel Dry Cask in use at the Haddam Neck Plant (HNP) Independent Spent Fuel Storage Installation (ISFSI)
Haddam Neck Plant Registration of Spent Fuel Dry Cask in use at the Haddam Neck Plant (HNP) Independent Spent Fuel Storage Installation (ISFSI)
In accordance with 10 CFR 72.212(b)(1)(ii), Connecticut Yankee Atomic Power Company (CYAPCO) is registering the use of a spent fuel dry cask to store spent fuel under a 10 CFR Part 72 general license at the HNP ISFSI.
In accordance with 10 CFR 72.212(b)(1)(ii), Connecticut Yankee Atomic Power Company (CYAPCO) is registering the use of a spent fuel dry cask to store spent fuel under a 10 CFR Part 72 general license at the HNP ISFSI.
Line 25: Line 27:


==Title:==
==Title:==
G. P. van Noordennen, Regulatory Affairs Manager Cask Certification No.: Certificate of Compliance 1025, Amendment No. 3, October 1, 2003 Cask'-Model No:: NAC-MPC                             -            - --
G. P. van Noordennen, Regulatory Affairs Manager Cask Certification No.: Certificate of Compliance 1025, Amendment No. 3, October 1, 2003 Cask'-Model No:: NAC-MPC  
                                            ..        .  .    .  .      ~~~~~~~~-       ............
~~~~~~~~-  
                                                                                                              !J'M1)S))WOt
!J'M1)S))WOt


- 4 Document Control Center CY-04-214 / Page 2 Cask Identification Nos.: Transportable storage canister (TSC) Identification No.
4 Document Control Center CY-04-214 / Page 2 Cask Identification Nos.: Transportable storage canister (TSC) Identification No.
CY-MPC-TSC-414-04 Vertical Concrete Cask (VCC) Identification No.: CY-VCC-04 Date in Service: October 18, 2004 There are no regulatory commitments contained in this letter.
CY-MPC-TSC-414-04 Vertical Concrete Cask (VCC) Identification No.: CY-VCC-04 Date in Service: October 18, 2004 There are no regulatory commitments contained in this letter.
If you should have any questions regarding this submittal, please contact me at (860) 267-3938.
If you should have any questions regarding this submittal, please contact me at (860) 267-3938.
Sincerely,
Sincerely, Gerard P. van Noordennen Regulatory Affairs Manager
                                                                        /   -;at-e Gerard P. van Noordennen                Date Regulatory Affairs Manager cc: S. J. Collins, NRC Region 1 Administrator T. B. Smith, NRC Project Manager, Haddam Neck Plant R. R. Bellamy, Chief, Decommissioning and Laboratory Branch, NRC Region 1 E. L. Wilds, Jr., Director, CT DEP, Monitoring and Radiation Division}}
/ -;at  
-e Date cc: S. J. Collins, NRC Region 1 Administrator T. B. Smith, NRC Project Manager, Haddam Neck Plant R. R. Bellamy, Chief, Decommissioning and Laboratory Branch, NRC Region 1 E. L. Wilds, Jr., Director, CT DEP, Monitoring and Radiation Division}}

Latest revision as of 23:53, 15 January 2025

Registration of Spent Fuel Dry Cask in Use at the Haddam Neck Plant (HNP) Independent Spent Fuel Storage Installation (ISFSI)
ML043080110
Person / Time
Site: Haddam Neck, 07201025  File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 10/25/2004
From: Gerard van Noordennen
Connecticut Yankee Atomic Power Co
To:
Document Control Desk, NRC/NMSS/SFPO
References
+KBR1SISP20050509, -RFPFR, CY-04-214, FOIA/PA-2005-0203
Download: ML043080110 (2)


Text

CONNECTICUT YANKEE ATOMIC POWER COMPANY HADDAM NECK PLANT 362 INJUN HOLLOW ROAD

  • EAST HAMPTON, CT 06424-3099

_O1 2 5 20 CY-04-214 OCT 25 ~

License No. DPR-61 Docket No. 50-213 Docket No. 72-0039 Re: 10 CFR 72.212 Director, Spent Fuel Project Office, Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Attention: Document Control Desk

-Washington,-DC 20555 -

Haddam Neck Plant Registration of Spent Fuel Dry Cask in use at the Haddam Neck Plant (HNP) Independent Spent Fuel Storage Installation (ISFSI)

In accordance with 10 CFR 72.212(b)(1)(ii), Connecticut Yankee Atomic Power Company (CYAPCO) is registering the use of a spent fuel dry cask to store spent fuel under a 10 CFR Part 72 general license at the HNP ISFSI.

Licensee's Name: Connecticut Yankee Atomic Power Company Licensee's Address: Haddam Neck Plant 362 Injun Hollow Road East Hampton, CT 06424-3099 Reactor License Number: DPR-61 Reactor Docket No.: 50-213 ISFSI Docket No.: 72-0039 Contact Name and

Title:

G. P. van Noordennen, Regulatory Affairs Manager Cask Certification No.: Certificate of Compliance 1025, Amendment No. 3, October 1, 2003 Cask'-Model No:: NAC-MPC

~~~~~~~~-

!J'M1)S))WOt

4 Document Control Center CY-04-214 / Page 2 Cask Identification Nos.: Transportable storage canister (TSC) Identification No.

CY-MPC-TSC-414-04 Vertical Concrete Cask (VCC) Identification No.: CY-VCC-04 Date in Service: October 18, 2004 There are no regulatory commitments contained in this letter.

If you should have any questions regarding this submittal, please contact me at (860) 267-3938.

Sincerely, Gerard P. van Noordennen Regulatory Affairs Manager

/ -;at

-e Date cc: S. J. Collins, NRC Region 1 Administrator T. B. Smith, NRC Project Manager, Haddam Neck Plant R. R. Bellamy, Chief, Decommissioning and Laboratory Branch, NRC Region 1 E. L. Wilds, Jr., Director, CT DEP, Monitoring and Radiation Division