| Line 1: |
Line 1: |
| {{Adams
| | #REDIRECT [[NRC-2008-0332, Comment (027) from Timothy S. Rausch on PR-50 and PR-52, Performance-Based Emergency Core Cooling Systems Cladding Acceptance Criteria]] |
| | number = ML14237A446
| |
| | issue date = 08/21/2014
| |
| | title = Comment (027) from Timothy S. Rausch on PR-50 and PR-52, Performance-Based Emergency Core Cooling Systems Cladding Acceptance Criteria
| |
| | author name = Rausch T
| |
| | author affiliation = PPL Susquehanna, LLC
| |
| | addressee name = Vietti-Cook A
| |
| | addressee affiliation = NRC/SECY/RAS
| |
| | docket = 05000387, 05000388
| |
| | license number =
| |
| | contact person = SECY/RAS
| |
| | case reference number = 79FR16105 00027, NRC-2008-0332, NRC-2012-0041, NRC-2012-0042, NRC-2012-0043, PLA-7229, PR-50, PR-52
| |
| | document type = Rulemaking-Comment
| |
| | page count = 1
| |
| }}
| |
| | |
| =Text=
| |
| {{#Wiki_filter:PR-10 CFR Parts 50 and 52 27 79 FR 16105 Timothy S. Rausch PPL Susquehanna, LLC Senior Vice President & Chief Nuclear Officer 769 Salem Boulevard Berwick, PA 18603 Tel. 570.542.3345 Fax 570.542.1504 tsrausch @pplweb.com AUG 21 2014 10 CFR 50.46c 79FR16106 Ms. Annette L. Vietti-Cook Secretary U.S. Nuclear Regulatory Commission Attn: Rulemakings and Adjudications Staff Washington, DC 20555-0001 SUSQUEHANNA STEAM ELECTRIC STATION COMMENTS CONCERNING PROPOSED RULE Docket No. 50-387 and 10 CFR PART 50.46C No. 50-388, and PLA-7229 Docket ID NRC-2008-0332
| |
| | |
| ==Reference:==
| |
| NEI Letter to NRC, "Comments on 'Performance-Based Emergency Core Cooling Systems Cladding Acceptance Criteria' (Docket ID NRC-2008-0332) (Federal Register Notice 79FRI6106), " dated August 21, 2014.
| |
| The purpose of this letter is to provide PPL Susquehanna, LLC's (PPL) endorsement, in entirety, of the positions stated in the referenced letter from the Nuclear Energy Institute (NEI).
| |
| PPL appreciates the opportunity to submit these comments. If you have any questions regarding these comments or require further information, please contact Mr. John L.
| |
| Tripoli, Manager- Nuclear Regulatory Affairs, at (570) 542-3100.
| |
| Sincerely, T. S. Rausch Copy: NRC Region I Mr. J. Greives, NRC Sr. Resident Inspector Mr. J. Whited, NRC Project Manager Mr. L. Winker, PA DEP/BRP}}
| |
| | |
| =Text=
| |
| {{#Wiki_filter:PR-10 CFR Parts 50 and 52 27 79 FR 16105 Timothy S. Rausch PPL Susquehanna, LLC Senior Vice President & Chief Nuclear Officer 769 Salem Boulevard Berwick, PA 18603 Tel. 570.542.3345 Fax 570.542.1504 tsrausch @pplweb.com AUG 21 2014 10 CFR 50.46c 79FR16106 Ms. Annette L. Vietti-Cook Secretary U.S. Nuclear Regulatory Commission Attn: Rulemakings and Adjudications Staff Washington, DC 20555-0001 SUSQUEHANNA STEAM ELECTRIC STATION COMMENTS CONCERNING PROPOSED RULE Docket No. 50-387 and 10 CFR PART 50.46C No. 50-388, and PLA-7229 Docket ID NRC-2008-0332
| |
| | |
| ==Reference:==
| |
| NEI Letter to NRC, "Comments on 'Performance-Based Emergency Core Cooling Systems Cladding Acceptance Criteria' (Docket ID NRC-2008-0332) (Federal Register Notice 79FRI6106), " dated August 21, 2014.
| |
| The purpose of this letter is to provide PPL Susquehanna, LLC's (PPL) endorsement, in entirety, of the positions stated in the referenced letter from the Nuclear Energy Institute (NEI).
| |
| PPL appreciates the opportunity to submit these comments. If you have any questions regarding these comments or require further information, please contact Mr. John L.
| |
| Tripoli, Manager- Nuclear Regulatory Affairs, at (570) 542-3100.
| |
| Sincerely, T. S. Rausch Copy: NRC Region I Mr. J. Greives, NRC Sr. Resident Inspector Mr. J. Whited, NRC Project Manager Mr. L. Winker, PA DEP/BRP}}
| |