{{Adams
#REDIRECT [[05000272/LER-1981-012-03, /03L-0:on 810204,fire Pump 2 in Fire Suppression Water Sys Declared Inoperable for Maint on Leaking Inlet Cooling Water Line.Caused by Leaking Corrugated Stainless Steel Hose Connecting Common Cooling Water Piping]]
| number = ML18085A942
| issue date = 02/19/1981
| title = LER 81-012/03L-0:on 810204,fire Pump 2 in Fire Suppression Water Sys Declared Inoperable for Maint on Leaking Inlet Cooling Water Line.Caused by Leaking Corrugated Stainless Steel Hose Connecting Common Cooling Water Piping
| author name = Steele W
| author affiliation = PUBLIC SERVICE ELECTRIC & GAS CO. OF NEW JERSEY
| addressee name =
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
| docket = 05000272
| license number =
| contact person =
| document report number = LER-81-012-03L, LER-81-12-3L, NUDOCS 8102270723
| package number = ML18085A938
| document type = LICENSEE EVENT REPORT (SEE ALSO AO,RO), TEXT-SAFETY REPORT
| page count = 1
}}
 
=Text=
{{#Wiki_filter:NRC FORM 366                                                                                                                            U.S. NUCLEAR REGULATORY COMMISSION (7-;t7l __ -- ;;.
                                                                              -LICENSEE EVENT REPORT
* C::ON,TRO,L J
I BLOCK: ~1_..__,__....___...__........__.6~            IIi"              (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) fB:D *IN- IJ 7        8    9 Is    I LICENSEE CODE GI sl1 Kvl 01 oj 14      15
                                                                                    -I  ol ol ol ol ol -1 ol olG)l4 LICENSE NUMBER                      25      26 I 1l    1l 1l 1l©I LICENSE TYPE      JO I
57 CAT 58 10 CON'T
~                    =~~~~~ LlJ©I ol sl olo I ol 2l 1l 21G)lo 1210 l4 ls t1l@I012111918111@
7        8                        60              61              DOCKET 'llUMBEA              68    69        EVENT DATE            74      75      REPORT DATE        BO _
EVENT DESCRIPTION AND PROBABLc CONSEQUENCES@
I During normal operation on 2/4/81, the #2 Fire Pump in the Fire Suppression Water
((JI] I System was declared inoperable in order to repair a leaking inlet cooling water line.I
~                  Action Statement 3.7.10.l(a) was entered at 1625 hours.
[ffi)
[ill]
ITID
[ill]
7        8 9                                                                                                                                                                        80 SYSTEM                CAUSE            CAUSE                                                      COMP.        VALVE CODE                CODE          SUBCODE                COMPONENT CODE                    SUB CODE        SUBCOOE
[ill]                                  IA      I Bl@ L!J@ L!..J@) I                                  PII I Pl El          XI x1@ ~ ~@
7        8                            9            10            11              12            13                              18          19            20 SEQUENTIAL                          OCCLJRAENCE          REPORT                    REVISION r.-:;-. LE A-Ao CV ENT YEAR                                            REPORT NO.                              CODE              TYPE                      NC.
              \;.:.; REPORT NUMBER I  8    11    I          l==1              10 11 12      I        I/I            Io 13 I              L!J          L=J          LQJ 21          22          23                24          26        27            28      29          30            31          32 ACTION FUTURE                        EFFECT            SHUTDOWN                            t::::::i ATTACHMENT          NPR0-4      PRIME COMP.          COMPONENT TAKEr.i        ACTION                ON PLANT            METHOD                    HOURS    ~          SUBMITTED      FORM SUB.        SUPPLIER          MANUFACTURER w@W@)                                ~@                  ~                10 10 10        1° 40I~@                    ~              ~@            I  Al 3js1 Bl@
33            34                    35                  36                37                          41              42              43            44            47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS                                    @
IJJ]J I A corrugated stainless steel hose that connects the common cooling water piping shared by the pump and its starting diesel was leaking.                                                              The hose was replaced in kind.            The Action Statement was terminated at 2140 hours.
rrrn 7        B    9                                                                                                                                                                      80 FACILITY                                                                                M~oom                                                            ~
STATUS                % POWER                            OTHER STATUS                DISCOVERY                              DISCOVERY DESCRIPTION ~
EJI]8        ~@ 11                    I 0 I 012J@I- - 1 3 - - - -N/A                                ~~._l_O_p_e_r_a_t_o_r_o_b_s_e_r_v_a_t_i_*o_n___________,
7            9                  10                                            -'"--,.---44 45          46                                                              80 ACTIVITY          CONTENT                                                      ~
RELEASED OF RELEASE                                AMOUNT OF ACTIVITY ~                                                        LOCATION OF RELEASE      @
~~@W@I*                                                                      N/A                                                                    N/A 7      8    9                10              11                                            44            45                                                                    BO PERSONNEL EXPOSURES                                    (:;;;.,
NUMBER          t::::::i TYPE        DESCRIPTION~
EI?]
7        B 9 I 0 .I    0  I 011lL!J@    12          1._3_ _ _ _
N    A
                                                                            ...._~------------------------------8                                                                    ...
0 Pl!RSONNEL INJURIES                        (;"";\
r.;-r;:"'1          NUMBER                    DESCRIPTION6
~I 1      - 8 9 ol ol oj@).._~~~~~N~A~~~~---:-~----------~------------------
11          12                                                                                                                                    BO LOSS OF OR DAMAGE TO FACILITY                    l.iJ\
TYPE            DESCRIPTION                      ~
~
7        B 9 l;J@).__~~~~~~--=N~A~~~~~~~~~~~~~~~~~~~~~~
10                                                                                                                                                      BO PUBLICITY                    C\
ISSUED/,;;\ DESCRIPTION~                                                        81 0221 ..,                                                            NRC USE ONL y        .,
I2I£)
7        8 9 L!Ll6l                                                        N/A            -                  (}  ,;Q3 1 - - - - - - - - - - . = : . . t . . . = . - - - - - - - - - - - - - - - - - - - - - J 6 B 69 11111111JI11              f!
80 ;
0 NAMEOFPREPARER ____                      w_._J_._s_t_e_e_l_e__________                                    PHONE: _ _6_0_9_-_9_3_5_-_0_9_9_B_ _ __          II.
                                                                                                                                                                                          "}}

Latest revision as of 05:17, 6 January 2025