ML19341A034: Difference between revisions

From kanterella
Jump to navigation Jump to search
Created page by program invented by StriderTol
StriderTol Bot change
 
Line 1: Line 1:
{{Adams
#REDIRECT [[05000267/LER-1980-077-03, /03L-0:on 801224,one Bearing Water Makeup Pump Removed from Svc During Normal Operation.Caused by Need to Repair Valve Leak.Valves Repaired & Pump Returned to Svc]]
| number = ML19341A034
| issue date = 01/14/1981
| title = LER 80-077/03L-0:on 801224,one Bearing Water Makeup Pump Removed from Svc During Normal Operation.Caused by Need to Repair Valve Leak.Valves Repaired & Pump Returned to Svc
| author name = Gahm J
| author affiliation = PUBLIC SERVICE CO. OF COLORADO
| addressee name =
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
| docket = 05000267
| license number =
| contact person =
| document report number = LER-80-077-03L, LER-80-77-3L, NUDOCS 8101210488
| package number = ML19341A030
| document type = LICENSEE EVENT REPORT (SEE ALSO AO,RO), TEXT-SAFETY REPORT
| page count = 3
}}
 
=Text=
{{#Wiki_filter:73 l
v                                                -        -
t ,NRd PORM 364                                                                                                              U. S. NUCLEAR REIULAT!~.Y COMMISSION LICENSEE EVENT REPORT CONTROL BLOCK: l 1
l  l    l    l    l lh 6
(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) lo 118 l9l C l LICENSEE 7
O ! F lCCCE  S I V l141 l@l 15 0 l 0 l -l 0LICENSE l 0 l 0NLMSER l 0 l 0 l - l 0 l 04$l@i264 l 1LICENSE l 1 l 2TYPE l 0J0l@lS F GAT l 58 l@
CON'T lolil 7        4          ST3"CE 1 @l0l5l0l0l0l2lSl J.idl1l2l2l4l8l0l@l0l1l1l41811l@
60          61          DOCK ET NUM8 E R                  69      EVENT O ATE            74      75      RE80RT DATE          80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h lol2l ] During normal operation, one bearing water makeup pump was removed f rom service to                                                                                  i l o l a i l repair a valve. The valve leak had not rendered the oumo inocerable. Operation at                                                                                i lolAl l power with one bearing water makeup pump inocerable constitutes operation in a de-                                                                                  1 I o I s i l graded mode of LCO 4.2.2 and is reportable per Fort St. Vrain Technical Specification l ~
f a 16 i LAC 7.5.2(b)2.                      There was no effect on public health or safeev. Redund ant ecutoment                                                          I l o l 7 l l was available and operable. A similar event was reported as Rn 79-26.                                                                                          I I )la I I                                                                                                                                                            ,._)
SYSTEU        CAUSE          CAUSE                                                    COVP.          VAL.E t
COCE          CCCE        SL8COOE                COMPONENT CODE                  SL8C00E          SUSCCCE io!al                            I C l a lg [_x j@ l Z I@ lV l A l1. lV lE lx l@ l El@ [D_J @
7        8                      9        10        11 _          12            13                            is          19              20
                                        ,,,                                    SECUENTIAL                      OCCU R R E NCE        REPCRT                      REVfSION lee 40      EVENTvtAR                            REPORT NO.                          CCDE                TYPE                          NO.
                        @ ,R E              l8 l0 l          l-l            l0 l7 l7 l            y            l 0l 3l 3        29 lLl 30 l-l          l0 l 32
_ 21        ;;      23            24          26        27                                                  31 K N AC ON              ON8 TANT        VE                      dOURS          S8 i              PCR b 8.          SLP8LE              VANVPAC ogg Ixl@lzl@                  Lz_J@          17l@            10101010 l                IV l@
48 l sl@ In l@                      I4AW l 0 I3 l 0-l@
JJ        34              JS              36            31                  40                    42                43                              47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS
                                                                                                                                                                    ~
t i t a i ] The cause of this event was the removal from service of one bearine water makeuo                                                                              l li ii i ! pump while the reactor was at power. The eumo was returned to service af ter the                                                                                1 i , i ; , l valve tepair was complete. The valve is a carbon stael,150 pound, 3 inch, gate                                                                                l
          ,,,3l        l valve, Model 5202WE, manufactured bv Walworth.                                                                                                            l l
Ll Lt.) I                                                                                                                                                              80 7      8 9 ST$N              % POWER                    CTHER STATUS              $15      RY                          CISCOVERY OESCRIPTicN l        lt i s l W@ l 0 l 7 l 0 52[@luN/A                                                l    l A l@l Observed by Operator                                                        l 44    as        se                                                                    a0 l
7 a A$TiviTY Co'0 TENT                                                                                                                                                    (
RELEASE                              AMOUNT OP ACTivlTY                                                    LOCATION OP RELEASE lt Is l W @D OFRELEASEW Q l N/Al                                                            l N/A                                                                        l 7      4 9              to          11                                    44            45                                                                          30 8ERSONNEL EXPCSLRES                                                                                                                                            l NUU8ER            TYPE      CESCRIPTION
,        l i l 7 l l 0 l 0 l 0 ]@l Z l@l N/A                                                                                                                                      l      l PERSONNE L INJU IES I                            NUMBER            DESCR1PTION li la 8t 10l 7            9 01 Ol@l12 N/A 11 I
80 LOSS OF CR C AMAGE TO PACILITY TYPE      OESCR18 TION Ii 191 LZ_j@l N/A                                                                                                                                                        l 7        8 9            10                                                                                                                                              So PV8LICITY                                                                                                                      NRC USE CNLY DESCRIPTION
* do] ISSUEDl -N/A                                            .      / _ o -, # , o , n                                                l    IIIIIIIIi!IIl}
NAME OP PREPARER                                                                            PHONE:            303 785-2224                          .
7
 
r.
REPORT DATE:          January 14, 1981              REPORTABLE OCCURRENCE 80-077 ISSUE O OCCURRENCE DATE:      December 24, 1980            Page 1 of 2 FORT ST. VRAIN NUCLEAR GENERATING STATION PUBLIC SERVICE COMPANY OF COLORADO 16805 WEID COUNTY ROAD 19 1/2 PLATTEVILLE, COLORADO 80651 REPORT NO. 50-267/80-077/03-L-0 Final IDENTIFICATION OF OCCURRENCE:
One bearing water makeup pump was removed from service to repair a leaking valve bonnet. This situation constitutes operation in a degraded mode of LCO 4.2.2 and is reportable per Fort St. Vrain Technical Specification AC 7.5.2(b)2.
EVENT DESCRIPTION:
On December 24, 1980, while operating at 70% thermal power and 215 MW elec-trical, a valve in the suction path of one of the two bearing water makeup pumps developed a bonnet leak, which did not, in itself, render the pump inoperable. Later the same day, it was decided to remove the pump from service to repair the valve leak.
The bearing water makeup gump was out of service from 0930 hours until 1030 hours on Decemtr 24, 1980.
CAUSE DESCRIPTION:
The cause of this event was the removal from service of the bearing water makeup pump while the reactor was at power.
CORRECTIVE ACTION:
Upon completion of the valve repair, the pump was returned to service.
No further corrective action is anticipated or required.
 
                ~
a t  '
REPORTABLE OCCURRENCE 80-077 ISSUE O Page 2 of 2 Prepared By:  8          [    , M Richard R. Frost Technical Services Technician Reviewed By:
                          . W f. ahm Tectinical Serivces Supervisor Reviewed By:
Frank M. Mathie Operations Manager Approved By:            Fmj                                      l Don Warembourg          g Manager, Nuclear Production l
l I
'}}

Latest revision as of 18:39, 24 December 2024