SOUTH CAROLINA ELECTRIC & GAS COMPANY POST OFFICE BOX 764 | SOUTH CAROLINA ELECTRIC & GAS COMPANY POST OFFICE BOX 764 COLUMBI A, S. C. 29218 March 26,1982 5 | ||
COLUMBI A, S. C. 29218 | -i i | ||
March 26,1982 | Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Ccmmission rv Region II, Suite 3100 101 Marietta Street, N.W. | ||
Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Ccmmission | Atlanta, GA 30303 | ||
==Subject:== | ==Subject:== | ||
V. C. Sunmer Nuclear Station Docket No. 50/395 Substantial Safety Hazard or Significant Deficiency, Containment Isolation Globe Valves NE File: 3.1050 | V. C. Sunmer Nuclear Station Docket No. 50/395 Substantial Safety Hazard or Significant Deficiency, Containment Isolation Globe Valves NE File: | ||
3.1050 | |||
==Dear Mr. O'Reilly:== | ==Dear Mr. O'Reilly:== | ||
South Carolina Electric and Gas Compara reported a potential substantial safety hazard or potential significant deficiency as defined by 10CFR21 and 10CFR50.55e to Mr. Virgil Brownlee at the NRC Region II office on December 22, 1981. An interim report was written to Mr. James P. O'Reilly on January 20, 1982. The item involved Westinghouse globe valves (Limitorque Actuated) used for outside containment isolation of the seal injection lines not seating tight enough to restrict the flow of wai.er which could result in radioactive leakage to the atmosphere. | South Carolina Electric and Gas Compara reported a potential substantial safety hazard or potential significant deficiency as defined by 10CFR21 and 10CFR50.55e to Mr. Virgil Brownlee at the NRC Region II office on December 22, 1981. An interim report was written to Mr. James P. O'Reilly on January 20, 1982. The item involved Westinghouse globe valves (Limitorque Actuated) used for outside containment isolation of the seal injection lines not seating tight enough to restrict the flow of wai.er which could result in radioactive leakage to the atmosphere. | ||
On March 19, 1982, a functional test of the containment isolation globe valves was conducted to determine if the valves would seat tight enough to seal off the flow of m ter. The globe valves wre operated over the full . range of torque settings. Tha tests demonstratal that the globe valves will seal off under full differential pressure. | On March 19, 1982, a functional test of the containment isolation globe valves was conducted to determine if the valves would seat tight enough to seal off the flow of m ter. The globe valves wre operated over the full. range of torque settings. Tha tests demonstratal that the globe valves will seal off under full differential pressure. | ||
Therefore, this is not a substantial safety hazard or significant deficiency. This letter serves as a final report. | Therefore, this is not a substantial safety hazard or significant deficiency. This letter serves as a final report. | ||
If you have any questions, please let us know. | If you have any questions, please let us know. | ||
Very truly yours, | Very truly yours, t4 T. C. Nichols, Jr. | ||
DH:'ICN:tdh cc: see page two 8205210425 820326 gC PDR ADOCK 05000395 S | |||
DH:'ICN:tdh cc: see page two 8205210425 820326 | PDR gg4 7 | ||
PDR ADOCK 05000395 | L / | ||
'~ | '~ | ||
Mr. J. P. O'Reilly Page two March 26, 1982 cc: | Mr. J. P. O'Reilly Page two March 26, 1982 cc: | ||
V. C. Summr T. C. Nichols, Jr. | |||
G. H. Fischer H. N. Cyrus H. T. Babb D. A. Naunun M. B. hhitaker, Jr. | G. H. Fischer H. N. Cyrus H. T. Babb D. A. Naunun M. B. hhitaker, Jr. | ||
W. A. Williams, Jr. | W. A. Williams, Jr. | ||
O. S. Bradham R. B. Clary M. N. Browne A. R. Koon H. Radin O. W. Dixcn , Jr. | O. S. Bradham R. B. Clary M. N. Browne A. R. Koon H. Radin O. W. Dixcn, Jr. | ||
Site Q. A. | Site Q. A. | ||
C. L. Ligon (NSRC) | C. L. Ligon (NSRC) | ||
| Line 50: | Line 48: | ||
B. A. Bursey J. C. Ruoff I&E (Washington) | B. A. Bursey J. C. Ruoff I&E (Washington) | ||
Document Management Branch | Document Management Branch | ||
*(55e,21, LER only) | |||
NPCF File | NPCF File}} | ||
Latest revision as of 05:03, 18 December 2024
| ML20052H771 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 03/26/1982 |
| From: | Nichols T SOUTH CAROLINA ELECTRIC & GAS CO. |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| References | |
| REF-PT21-82 10CFR-050.55E, 10CFR-50.55E, NUDOCS 8205210425 | |
| Download: ML20052H771 (2) | |
Text
J e
SOUTH CAROLINA ELECTRIC & GAS COMPANY POST OFFICE BOX 764 COLUMBI A, S. C. 29218 March 26,1982 5
-i i
Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Ccmmission rv Region II, Suite 3100 101 Marietta Street, N.W.
Atlanta, GA 30303
Subject:
V. C. Sunmer Nuclear Station Docket No. 50/395 Substantial Safety Hazard or Significant Deficiency, Containment Isolation Globe Valves NE File:
3.1050
Dear Mr. O'Reilly:
South Carolina Electric and Gas Compara reported a potential substantial safety hazard or potential significant deficiency as defined by 10CFR21 and 10CFR50.55e to Mr. Virgil Brownlee at the NRC Region II office on December 22, 1981. An interim report was written to Mr. James P. O'Reilly on January 20, 1982. The item involved Westinghouse globe valves (Limitorque Actuated) used for outside containment isolation of the seal injection lines not seating tight enough to restrict the flow of wai.er which could result in radioactive leakage to the atmosphere.
On March 19, 1982, a functional test of the containment isolation globe valves was conducted to determine if the valves would seat tight enough to seal off the flow of m ter. The globe valves wre operated over the full. range of torque settings. Tha tests demonstratal that the globe valves will seal off under full differential pressure.
Therefore, this is not a substantial safety hazard or significant deficiency. This letter serves as a final report.
If you have any questions, please let us know.
Very truly yours, t4 T. C. Nichols, Jr.
DH:'ICN:tdh cc: see page two 8205210425 820326 gC PDR ADOCK 05000395 S
PDR gg4 7
L /
'~
Mr. J. P. O'Reilly Page two March 26, 1982 cc:
V. C. Summr T. C. Nichols, Jr.
G. H. Fischer H. N. Cyrus H. T. Babb D. A. Naunun M. B. hhitaker, Jr.
W. A. Williams, Jr.
O. S. Bradham R. B. Clary M. N. Browne A. R. Koon H. Radin O. W. Dixcn, Jr.
Site Q. A.
C. L. Ligon (NSRC)
G. J. Braddick J. L. Skolds J. B. Knotts, Jr.
B. A. Bursey J. C. Ruoff I&E (Washington)
Document Management Branch
- (55e,21, LER only)
NPCF File