ENS 41761: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 06/07/2005 EDT | | event date = 06/07/2005 EDT | ||
| last update date = 06/10/2005 | | last update date = 06/10/2005 | ||
| title = Part 21 Report Involving | | title = Part 21 Report Involving a Potential for Premature Failure of Control Rod Instrumentation Power Supply | ||
| event text = Ametek Solid State Controls produces AC-DC power supplies that are used at several nuclear power plants. Ametek states that its Series AC-DC power supplies may have a problem with premature failure. The specific Model Numbers affected are as follows: | | event text = Ametek Solid State Controls produces AC-DC power supplies that are used at several nuclear power plants. Ametek states that its Series AC-DC power supplies may have a problem with premature failure. The specific Model Numbers affected are as follows: | ||
85-RP1510-00 | 85-RP1510-00 | ||
85-RP4804-00 | 85-RP4804-00 | ||
85-RP4808-00 | 85-RP4808-00 | ||
85-RP DUAL- | 85-RP DUAL-4807\1 | ||
Ametek states that an intermittent loss of continuity in a magnet wire connector may cause overheating in a lug and transformer which could eventually result in a premature failure of the power supply ( within approximately two years of initial service). The problem was discovered during testing of a power supplies by Ametek. No nuclear power plants have reported any problems with the power supplies. | Ametek states that an intermittent loss of continuity in a magnet wire connector may cause overheating in a lug and transformer which could eventually result in a premature failure of the power supply ( within approximately two years of initial service). The problem was discovered during testing of a power supplies by Ametek. No nuclear power plants have reported any problems with the power supplies. | ||
Ametek states that its records indicate that these power supplies were supplied to Braidwood, Byron, and DC Cook. | Ametek states that its records indicate that these power supplies were supplied to Braidwood, Byron, and DC Cook. |
Latest revision as of 21:20, 1 March 2018
Where | |
---|---|
Ametek Solid State Controls Columbus, Ohio (NRC Region 3) | |
Organization: | Ametek Solid State Controls |
Reporting | |
10 CFR 21.21 | |
Time - Person (Reporting Time:+77.12 h3.213 days <br />0.459 weeks <br />0.106 months <br />) | |
Opened: | Bob George 09:07 Jun 10, 2005 |
NRC Officer: | Bill Huffman |
Last Updated: | Jun 10, 2005 |
41761 - NRC Website | |