ENS 44516: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 09/23/2008 15:00 EDT
| event date = 09/23/2008 15:00 EDT
| last update date = 09/23/2008
| last update date = 09/23/2008
| title = Degraded Condition Due To Recirc Nozzle Weld Axial Crack
| title = Degraded Condition Due to Recirc Nozzle Weld Axial Crack
| event text = On September 23, 2008 at approximately 1500 [EDT] the James A. FitzPatrick Nuclear Power Plant was shutdown and operating in the refueling mode (Mode 5).  During an ISI inspection of the dissimilar metal weld on recirc nozzle N2-C an indication was identified.  Preliminary analysis of the data indicates a flaw in the nozzle weld that extends into the 'butter', is axially oriented, approximately 0.5 inches in length and 0.4 inches in depth.  There is no approved method for predicting crack growth in axially oriented flaws.  Therefore, the flaw can not evaluated in accordance with ASME Section XI.  This deficiency meets reporting criterion 10 CFR 50.72(b)(3)(ii).
| event text = On September 23, 2008 at approximately 1500 [EDT] the James A. FitzPatrick Nuclear Power Plant was shutdown and operating in the refueling mode (Mode 5).  During an ISI inspection of the dissimilar metal weld on recirc nozzle N2-C an indication was identified.  Preliminary analysis of the data indicates a flaw in the nozzle weld that extends into the 'butter', is axially oriented, approximately 0.5 inches in length and 0.4 inches in depth.  There is no approved method for predicting crack growth in axially oriented flaws.  Therefore, the flaw can not evaluated in accordance with ASME Section XI.  This deficiency meets reporting criterion 10 CFR 50.72(b)(3)(ii).
At this time four of the eight N2 Recirc Nozzles have been inspected with no other flaws or indications identified.  The remaining four N2 Nozzles are being inspected during this outage.
At this time four of the eight N2 Recirc Nozzles have been inspected with no other flaws or indications identified.  The remaining four N2 Nozzles are being inspected during this outage.

Latest revision as of 22:13, 1 March 2018

ENS 44516 +/-
Where
Fitzpatrick Constellation icon.png
New York (NRC Region 1)
Reporting
10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded
LER: 05000333/LER-2008-002
Time - Person (Reporting Time:+0.42 h0.0175 days <br />0.0025 weeks <br />5.75316e-4 months <br />)
Opened: Eugene Dorman
19:25 Sep 23, 2008
NRC Officer: Jeff Rotton
Last Updated: Sep 23, 2008
44516 - NRC Website
Loading map...