ML20128N747: Difference between revisions

From kanterella
Jump to navigation Jump to search
StriderTol Bot insert
 
StriderTol Bot change
 
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:.. _            _    _ __              _ _ .    -- _              __    . _
{{#Wiki_filter:..
    . Georgia Power Company 40 invemess Center Parkway Post Office Box 1295 Birmingham. Alabama 35201 Telophone 205 992 7122 Georgia Power C.K.McCoy                                                                     the souton ekxtnc syst+n M'o$"['""*'**'                           October 10, 1996 I
Georgia Power Company 40 invemess Center Parkway Post Office Box 1295 Birmingham. Alabama 35201 Telophone 205 992 7122 Georgia Power C.K.McCoy the souton ekxtnc syst+n M'o$"['""*'**'
LCV-0892 l
October 10, 1996 LCV-0892 Docket No. 50-425 U. S. Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 Gentlemen:
Docket No. 50-425 U. S. Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 Gentlemen:
i VOGTLE ELECTRIC GENERATING PLANT SPECIAL REPORT 2-96-3 NUMBER OF STEAM GENERATOR TUBES PLUGGED DURING 2R5 In accordance with the requirements of Vogtle Electric Generating Plant Technical Specifications (TS) sections 4.4.5.5.a and 6.8.2, Georgia Power Company submits this special report of the number of steam generator tubes plugged during the Unit 2 fifth refueling outage (2R5).
i VOGTLE ELECTRIC GENERATING PLANT                                                   .
As a result of the inservice inspection completed on September 30,1996, a total of five (5) tubes were plugged in steam generator #4. Four (4) of these tubes met or exceeded the Technical Specification limit for wall thinning (40 percent). The remaining tube was plugged as a precautionary measure. In addition, one (1) tube was plugged in steam generator #1, also due to the tube exceeding the Technical Specification limit for wall thinning. Complete inspection results will be submitted within 12 months per the requirement of Technical Specification 4.4.5.5.b.
SPECIAL REPORT 2-96-3 NUMBER OF STEAM GENERATOR                                                       '
Sincerely l
TUBES PLUGGED DURING 2R5 In accordance with the requirements of Vogtle Electric Generating Plant Technical Specifications (TS) sections 4.4.5.5.a and 6.8.2, Georgia Power Company submits this special report of the number of steam generator tubes plugged during the Unit 2 fifth                       l refueling outage (2R5).
z?.M' C. K. McCoy 0
As a result of the inservice inspection completed on September 30,1996, a total of five (5)                 ,
CKM/TEW xc: Continued next page 9610170031 961010 PDR ADOCK 05000425 O
tubes were plugged in steam generator #4. Four (4) of these tubes met or exceeded the                       I Technical Specification limit for wall thinning (40 percent). The remaining tube was plugged as a precautionary measure. In addition, one (1) tube was plugged in steam generator #1, also due to the tube exceeding the Technical Specification limit for wall thinning. Complete inspection results will be submitted within 12 months per the requirement of Technical Specification 4.4.5.5.b.                                                           l l
PDR
Sincerely                                                   l z?.M' C. K. McCoy                                               0 CKM/TEW xc: Continued next page 9610170031 961010 PDR     ADOCK 05000425 O                         PDR


  =
=
GeorgiaPower d U. S. Nuclear Regulatory Agency                         LCV-0892 Page 2 of 2 xc:   Georgia Power Company Mr. J. B. Beasley, Jr.
GeorgiaPower d U. S. Nuclear Regulatory Agency LCV-0892 Page 2 of 2 xc:
Mr. M. Sheibani NORMS U. S. Nuclear Regulatory Commission Mr. S. D. Ebneter, Regional Administrator Mr. L. L. Wheeler, Licensing Project Manager, NRR Mr. C. R. Ogle, Senior Resident Inspector, Vogtle l
Georgia Power Company Mr. J. B. Beasley, Jr.
l 4}}
Mr. M. Sheibani NORMS U. S. Nuclear Regulatory Commission Mr. S. D. Ebneter, Regional Administrator Mr. L. L. Wheeler, Licensing Project Manager, NRR Mr. C. R. Ogle, Senior Resident Inspector, Vogtle 4}}

Latest revision as of 14:00, 12 December 2024

Submits Special Rept 2-96-3 Re Number of SG Tubes Plugged During Fifth Refueling Outage
ML20128N747
Person / Time
Site: Vogtle 
Issue date: 10/10/1996
From: Mccoy C
GEORGIA POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
LCV-0892, LCV-892, NUDOCS 9610170031
Download: ML20128N747 (2)


Text

..

Georgia Power Company 40 invemess Center Parkway Post Office Box 1295 Birmingham. Alabama 35201 Telophone 205 992 7122 Georgia Power C.K.McCoy the souton ekxtnc syst+n M'o$"['""*'**'

October 10, 1996 LCV-0892 Docket No. 50-425 U. S. Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 Gentlemen:

i VOGTLE ELECTRIC GENERATING PLANT SPECIAL REPORT 2-96-3 NUMBER OF STEAM GENERATOR TUBES PLUGGED DURING 2R5 In accordance with the requirements of Vogtle Electric Generating Plant Technical Specifications (TS) sections 4.4.5.5.a and 6.8.2, Georgia Power Company submits this special report of the number of steam generator tubes plugged during the Unit 2 fifth refueling outage (2R5).

As a result of the inservice inspection completed on September 30,1996, a total of five (5) tubes were plugged in steam generator #4. Four (4) of these tubes met or exceeded the Technical Specification limit for wall thinning (40 percent). The remaining tube was plugged as a precautionary measure. In addition, one (1) tube was plugged in steam generator #1, also due to the tube exceeding the Technical Specification limit for wall thinning. Complete inspection results will be submitted within 12 months per the requirement of Technical Specification 4.4.5.5.b.