ENS 47759: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 03/21/2012 CDT | | event date = 03/21/2012 CDT | ||
| last update date = 03/22/2012 | | last update date = 03/22/2012 | ||
| title = Agreement State - Process Gauge Shutter Stuck | | title = Agreement State - Process Gauge Shutter Stuck in Open Position | ||
| event text = The State of Illinois reported the following information via email: | | event text = The State of Illinois reported the following information via email: | ||
The Wood River Refinery reported that a shutter mechanism on a fixed gauge (Ohmart Model SH-F1B, S.N. 2508CN) was found stuck in the open position during a routine survey and maintenance check. The gauge contained a 3.7 GBq (100 mCi) Cs-137 source. Staff were unable to return it to the shielded position. The gauge is in an unoccupied area. | The Wood River Refinery reported that a shutter mechanism on a fixed gauge (Ohmart Model SH-F1B, S.N. 2508CN) was found stuck in the open position during a routine survey and maintenance check. The gauge contained a 3.7 GBq (100 mCi) Cs-137 source. Staff were unable to return it to the shielded position. The gauge is in an unoccupied area. |
Revision as of 22:04, 1 March 2018
Where | |
---|---|
Wood River Refinery Roxana, Illinois (NRC Region 3) | |
License number: | Il-01282-01 |
Organization: | Illinois Emergency Mgmt. Agency |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+30.05 h1.252 days <br />0.179 weeks <br />0.0412 months <br />) | |
Opened: | Gibb Vinson 11:03 Mar 22, 2012 |
NRC Officer: | Bill Huffman |
Last Updated: | Mar 22, 2012 |
47759 - NRC Website | |