ML20235X414: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 1: Line 1:
{{Adams
#REDIRECT [[TXX-6573, Interim Deficiency Rept CP-86-63 Re Pipe Support Const. Initially Reported on 861016.Procedure CP-QAP-12-1, Mechanical Component Installation Verification, Revised. Next Rept to Be Submitted by 870930]]
| number = ML20235X414
| issue date = 07/20/1987
| title = Interim Deficiency Rept CP-86-63 Re Pipe Support Const. Initially Reported on 861016.Procedure CP-QAP-12-1, Mechanical Component Installation Verification, Revised. Next Rept to Be Submitted by 870930
| author name = Counsil W, Keeley G
| author affiliation = TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
| addressee name =
| addressee affiliation = NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
| docket = 05000445, 05000446
| license number =
| contact person =
| document report number = CP-86-63, TXX-6573, NUDOCS 8707240177
| document type = DEFICIENCY REPORTS (PER 10CFR50.55E & PART 21), TEXT-SAFETY REPORT
| page count = 2
}}
 
=Text=
{{#Wiki_filter:_ - - _ - _ - _ -- - - _ ____
j' M                            Log # TXX-6573 FE File # 10110 903.9
                                                                              =        =                    Ref: 10CFR50.55(e)
NELECTRIC uy    0, 1987      j wmiam c. counsu axmive va emuca U. S. Nuclear Regulatory Commission                                                        I Attn: Document Control Desk Washington, D.C. 20555 l                                   
 
==SUBJECT:==
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET NOS. 50-445 AND 50-446 PIPE SUPPORT INSTALLATIONS SDAR:  CP-86-63 (INTERIM REPORT)
Gentlemen:
By letter logged TXX-6027, dated October 16, 1986, we notified you of a reportable item involving pipe support construction deficiencies. This is a follow-up interim report on a reportable item under provisions of 10CFR50.55(e). Our last ' interim report was logged TXX-6391, dated April 16, 1987.                                                                                      ,
Previous reports described the extent of the Hardware ~ Validation Program (HVP) for the physical inspections of large and small bore safety related piping for            4 Unit 1. In conjunction with this program, an additional list of attributes has been formulated for physical inspection. These' attributes, identified as i
the Supplemental Inspection Checklist (SIC), are the result of requirements for additional information due to changes in the engineering analysis method or items deemed prudent and/or conservative to reinspect in concert with the HVP.                                                                                          ,
i Procedure CP-QAP-12.1, titled " Mechanical Component Installation                          i
;                                    Verification," has been revised to implement the SIC requirement. Any                        i l                                    deficiencies discovered during final inspections shall be documented via an NCR.and transmitted to Engineering for resolution and assignment of                          ,
appropriate actions.                                                                        !
y Seven (7) percent of the approximately 18,640 supports involved in the Unit 1 l                                    and common HVP and SIC reinspection have been completed. Our estimated                      ;
completion date is now January 1,1988.                                                    1 l
I B707240177 670720              R 6                                PDR    ADOCK 05000445 g                    PDR J
M Nonh Olive Street LB 81 Dallas, Texas 75201 k
(
 
r' TXX-6573                                                                    ;
July 20,1987 Page 2 i
Our next report will 've submitted on or before September 30, 1987.
l I
very truly yours,            i k            M l
W. G. Counsil i
f) /
By: k ,    f. L' -  '
j G. S. Kebley Manager,NucleF      nsing BSD/mlh c - Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3) 1 I
l 1
1 l
I l
l l
l l
[}}

Latest revision as of 17:34, 8 July 2023