ML20101J453: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot change)
(StriderTol Bot change)
 
Line 1: Line 1:
{{Adams
#REDIRECT [[3F0396-21, Special Rept 96-01:on 960218,RM-A1 Taken Out of Svc Due to Failure of Detector to Respond to Check Source.Replacement Detector from Stores & Bench Calibrate.Expects to Return RM-A1 to Svc Prior to Restart from Refueling Outage]]
| number = ML20101J453
| issue date = 03/26/1996
| title = Special Rept 96-01:on 960218,RM-A1 Taken Out of Svc Due to Failure of Detector to Respond to Check Source.Replacement Detector from Stores & Bench Calibrate.Expects to Return RM-A1 to Svc Prior to Restart from Refueling Outage
| author name = Hickle B
| author affiliation = FLORIDA POWER CORP.
| addressee name =
| addressee affiliation = NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
| docket = 05000302
| license number =
| contact person =
| document report number = 3F0396-21, 3F396-21, 96-01, 96-1, NUDOCS 9604010436
| document type = REPORTABLE OCCURRENCE REPORT (SEE ALSO AO LER), TEXT-SAFETY REPORT
| page count = 2
}}
 
=Text=
{{#Wiki_filter:l c      =
!        *e*
l l
l Florida Power CORPORATION cw rever una a mum March 26, 1996 3F0396-21 i
I U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555
 
==Subject:==
Special Report 96-01                                                                                        i l
 
==Dear Sir:==
j l
Attached is Special Report 96-01 which is submitted in accordance with the Florida Power Corporation Nuclear Operations Off-Site Dose Calculation Manual, Table 2-3, Action 29.
Should there be any questions, please contact this office.
Sincerely, LL n 82 ke B. J. Hickle, Director Nuclear Plant Operations                                                                                                l BJH/RLM Attachment xc:    Regional Administrator, Region II NRR Project Manager Senior Resident Inspector 9604010436 960326 DR  ADOCK0500g2 CRYSTAL RIVER ENERGY COMPLEX: 15760 W Power Line St . Crystal River, Florida 34428-6708 . (904) 795-6486 A Florida Progress Company                                                  ,
                                                                                                                            /[6"    i
 
s
      '9 SPECIAL REPORT 96-01 0FFSITE DOSE CALCULATION MANUAL REQUIRED RADIATION MONITOR UNAVAILABLE FOR GREATER THAN SEVEN DAYS This Special Report provides information concerning the reactor building purge        i exhaust high range radiation monitoring instrumentation (RM-A1).
On February 18, 1996, Florida Power Corporation's (FPC) Crystal River Unit 3 (CR-      ,
: 3) was in MODE 4 (H0T SHUTDOWN) at 0% power for a refueling outage. At 1851, RM-Al was taken out of service due to failure of the ietector to respond to the check source. At that time, Offsite Dose Calculation Manual (0DCM) table 2-3 Action #29 was entered which requires instrument restoration to service within seven days or submission of a Special Report within the next thirty days. As of March 26, 1996, the instrument has not been restored to service.
A Special Report outlines the actions taken, the cause of the inoperability, and      -
the plans and schedule for restoring the system to OPERABLE status.
Troubleshooting efforts indicate the detector failed to exhibit a linear response to a calibration source. A replacement detector will be obtained from stores and bench calibrated. If this unit is not acceptable, parts will be used to make a        ,
uorking detector. It is expected the RM-Al will be restored to service prior to        i restart from the refueling outage, currently scheduled for April 17, 1996.
J l
5 I
1}}