ML20134G140: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot change)
(StriderTol Bot change)
 
Line 1: Line 1:
{{Adams
#REDIRECT [[U-600208, Part 21 & Deficiency Rept (21-85-06) Re Potential Defect in Natl Valve & Mfg Co Sway Strut & Snubber Pipe Clamps. Evaluation Being Conducted]]
| number = ML20134G140
| issue date = 08/12/1985
| title = Part 21 & Deficiency Rept (21-85-06) Re Potential Defect in Natl Valve & Mfg Co Sway Strut & Snubber Pipe Clamps. Evaluation Being Conducted
| author name = Hall D
| author affiliation = ILLINOIS POWER CO.
| addressee name = Keppler J
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
| docket = 05000461
| license number =
| contact person =
| case reference number = REF-PT21-85
| document report number = (21-85-06), (21-85-6), U-600208, NUDOCS 8508230064
| document type = DEFICIENCY REPORTS (PER 10CFR50.55E & PART 21), TEXT-SAFETY REPORT
| page count = 1
}}
 
=Text=
{{#Wiki_filter:_ - _ _ - _ - - _ _ _ _ - - _ _ - - - - -  - - - _ - _ - - - - _ _ _ _ - _ - . _ - _ - - _ _ _ - - - _ _ _ - _ _ _ _ - . .
Dm6
        -                                                                                                                                                      U '600208 L16-85 (08 -12 )-L 1A.120 ILLIN0/S POWER COMPANY CLINTON POWER STATION. P.O. BCx 678, CLINTON ILLINOIS 61727 August 12, 1985 Docket.No. 50-461
                                  -Mr. James G. Keppler Regional Administrator Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois                                                                          60137
 
==Subject:==
10CFR Part 21 Defect Failure of Sway Strut and Snubber Pipe Clamps at Clinton Power Station (21-85-06)
 
==Dear Mr.'Keppler:==
 
In Illinois Power Company's letter to Mr. Frank Jablonski, NRC Region III, (Ref. U-10024,.1606-L, dated January 17, 1983), Illinois Power agreed to notify Region III of those~10CFR Part 21 defects that affect Clinton Power Station and that were previously reported to the Commission by. vendors or contractors. In accordance with that agree-ment, the following information is submitted:
l                                                Basic Engineers Division of National Valve and Manufac-l                                                turing Company has notified the Clinton Power Station l                                                of a Potential 10CFR21 Defect in its sway strut and snubber pipe clamps which may cause them to slip circumferentially around the pipe when a compressive load less than the faulted rated load is applied at an angle of 5' to the centerline.
Illinois Power is conducting an evaluatiot; of the reported' condition at the Clinton Power Station and will assure.that adequate corrective action is taken.
Sinc    ely yours, D.    . all Vice President JV/ lab cc:          NRC Resident Office Illinois Department of Nuclear Safety Director, Office of I&E, USNRC, Washington DC                                                                                  20555 INPO Records. center 8508230064 850812                                                                                                    AUb 14 PDR S
ADOCK 05000461 PDR                                                                I
                                                                                                                                                                                            )O ((19
                                                                                                                                                                                                      - _ _ _ _ _}}

Latest revision as of 17:24, 14 December 2021