PNO-II-86-045A, primary Sys Temp Dropped from 550 F to 465 F in 6 Minutes.Reactor Coolant Pumps Operated Throughout Event.Poor Human Factor Design Features Caused Operators Not to Be in Control: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
Line 1: Line 1:
{{Adams
#REDIRECT [[PNO-II-86-045, on 860627,four PORVs Opened,Dropping Primary Sys Pressure from 2,235 Psi to 702 Psi & Temp from 550 F to 450 F in 6 Minutes.Cause Under Investigation.Valves Closed & Safety Injection Initiated]]
| number = ML20212A343
| issue date = 07/01/1986
| title = PNO-II-86-045A:primary Sys Temp Dropped from 550 F to 465 F in 6 Minutes.Reactor Coolant Pumps Operated Throughout Event.Poor Human Factor Design Features Caused Operators Not to Be in Control
| author name = Burger C, Peebles T
| author affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
| addressee name =
| addressee affiliation =
| docket = 05000414
| license number =
| contact person =
| document report number = CAL, PNO-II-86-045A, PNO-II-86-45A, NUDOCS 8607280162
| document type = PRELIMINARY NOTIFICATION OF EVENT OR OCCURRENCE (PNO,, TEXT-INSPECTION & AUDIT & I&E CIRCULARS
| page count = 1
}}
{{#Wiki_filter:-
July 1, 1986 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE PN0-II-86-45A This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance.        The information is as initially received without verifi-cation or evaluation, and is basically all that is known by the Region II staff on this date.
FACILITY:    Duke Power Company #3-                    Licensee Emergency Classification:
Catawba Unit 2 #-                          X Notification of Unusual Event Docket No. 50-414                              Alert Rock Hill, South Carolina                      Site Area Emergency General Emergency Not Applicable
 
==SUBJECT:==
UNEXPECTED REACTOR DEPRESSURIZATION AND C00LDOWN -- UPDATE This PN updates PNO-II-86-45, issued on June 27.
Preliminary information obtained by the Augmented Inspection Team now on site indicates that, when the unit's four steam generator power operated relief valves (PORVs) opened during a test, primary system temperature dropped from 550 degrees Fahrenheit to 465 degrees (rather than 450 degrees) in six minutes -- within the allowable temperature change limits.
It has also now been learned that the reactor coolant pumps were operating throughout the event, and that poor human factors design features caused the operators not to maintain ccntrol during the test.
Region II issued a confirmation-of-action letter on June 30 documenting Duke Power's commitment not to restart the reactor without NRC concurrence.
Both Duke and NRC have responded to media inquiries.
1  The State of South Carolina has been informed.
This information is current as of 10 a.m. (EDT) today.
 
==Contact:==
C. Burger, 242-4198                              Tom Peebles, 242-5623 0                                  /
DISTRIBUTION H. Street / g          MNBb.SPhillips
(
E/W f.$          Q Willstel > MAIL:
,  Chairman Palladino EDO          NRR          IE      NMSS          ADM:DMB l  Comm. Roberts          PA                    OIA    RES          D0T: Trans Only l  Comm. Asselstine        MPA                  AE0D ,o              Applicable State Comm. Bernthal          ELD AirRightsl.g              p Comm. Zech                                    INP0 SECY                        SP              NSAC ACRS CA                                        P( bg$4 d,5[e PDR                          Regions: I'T/TIL Licensee: Eid >
(Reactor Licensees) M Applicable Resident Site.R 'J<3 86o728o162 860701 P