ENS 54886: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (StriderTol Bot change) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
Line 1: | Line 1: | ||
{{ENS notification | {{ENS notification | ||
| event number = 54886 | | event number = 54886 | ||
| facility = | | facility = | ||
| Organization = Texas Dept Of State Health Services | | Organization = Texas Dept Of State Health Services | ||
| license number = L 05384 | | license number = L 05384 | ||
Line 10: | Line 10: | ||
| utype = | | utype = | ||
| cfr = Agreement State | | cfr = Agreement State | ||
| emergency class = | | emergency class = Non Emergency | ||
| notification date = 09/05/2020 14:35 | | notification date = 09/05/2020 14:35 | ||
| notification by = Arthur Tucker | | notification by = Arthur Tucker | ||
Line 16: | Line 16: | ||
| event date = 09/05/2020 00:00 CDT | | event date = 09/05/2020 00:00 CDT | ||
| last update date = 09/05/2020 | | last update date = 09/05/2020 | ||
| title = Agreement State Report - Gauge Damaged When Struck by Vehicle | | title = <Td Align="Left" Scope="Row">Agreement State Report - Gauge Damaged When Struck by Vehicle | ||
| event text = The following was received from the Texas Department of State Health Services (the Agency) via email: | | event text = The following was received from the Texas Department of State Health Services (the Agency) via email: | ||
On September 5, 2020, The Agency was notified by the licensee's site radiation safety officer (SRSO) that a Humboldt EZ 5001 moisture/density gauge was damaged at a temporary job site when a bulldozer struck the gauge. The gauge contains a 40 milliCurie americium-241 source and a 10 milliCurie cesium-137 source. The cesium source was in the shielded position when the event occurred. The operating rod was bent, and the SRSO stated he did not believe the cesium source rod would move. The SRSO stated they performed radiation surveys around the gauge and the highest reading they obtained was 1.3 millirem per hour, which is a normal reading. The SRSO stated they were taking the gauge back to their storage location and would perform a leak test of the gauge. The event did not present an exposure risk to any individual. Additional information will be provided as it is received in accordance with SA-300. | On September 5, 2020, The Agency was notified by the licensee's site radiation safety officer (SRSO) that a Humboldt EZ 5001 moisture/density gauge was damaged at a temporary job site when a bulldozer struck the gauge. The gauge contains a 40 milliCurie americium-241 source and a 10 milliCurie cesium-137 source. The cesium source was in the shielded position when the event occurred. The operating rod was bent, and the SRSO stated he did not believe the cesium source rod would move. The SRSO stated they performed radiation surveys around the gauge and the highest reading they obtained was 1.3 millirem per hour, which is a normal reading. The SRSO stated they were taking the gauge back to their storage location and would perform a leak test of the gauge. The event did not present an exposure risk to any individual. Additional information will be provided as it is received in accordance with SA-300. |
Latest revision as of 11:21, 15 January 2021
Where | |
---|---|
Texas Dept Of State Health Services Carrollton, Texas (NRC Region 4) | |
License number: | L 05384 |
Organization: | Texas Dept Of State Health Services |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+9.58 h0.399 days <br />0.057 weeks <br />0.0131 months <br />) | |
Opened: | Arthur Tucker 14:35 Sep 5, 2020 |
NRC Officer: | Jeffrey Whited |
Last Updated: | Sep 5, 2020 |
54886 - NRC Website | |